The status for each component is either Optimal or Needs Attention.
11. Does each module display green LEDs only, and is the status Optimal for each
module component?
v
Yes
- Go to step 13.
v
No
- Go to step 12.
12. Diagnose and correct the fault.
a. To run the Recovery Guru, select the Recovery Guru toolbar button in the
Subsystem Management Window.
b. Complete the recovery procedure.
If the Recovery Guru directs you to replace a failed component, locate and
troubleshoot that component. See “Checking the LEDs” on page 73.
c. When the procedure is completed, rerun the Recovery Guru to ensure that
the problem has been corrected by selecting
Recheck
in the Recovery
Guru.
d. If the problem persists, contact IBM Customer and Technical Support.
13. Replace the bezel on the storage expansion enclosure, if applicable.
86
IBM System Storage DS4000 EXP810 Storage Expansion Enclosure: Installation, User’s and Maintenance Guide