numbers of the PCI slots. The integrated controller is
located in slot 9.
5. To enable the writing of messages to the
IBMCOM\LANTRAN.LOG file when a failover occurs:
a. Copy the file PCNETOS2.EXE from the OS2
directory of the diskette created by the
ServerGuide program to the hard disk drive.
b. Add the following statement to the CONFIG.SYS
file:
Run=
d
:\
path
\PCNETOS2.EXE
where
d and path are the drive and path to
which you copied PCNETOS2.EXE.
6. Restart the server.
The failover function is now enabled.
Configuring Failover on Windows NT
1. Install the redundant NIC adapter according to the
instructions provided with the adapter and in
“Installing or removing adapters” on page 57.
2. Use the ServerGuide CDs to install the AMD PCNet
Ethernet Family adapter device driver.
3. From the Windows NT desktop, select Control Panel,
then select the Network icon, then the Adapters tab.
4. Highlight one of the adapters that will be in the
redundant pair and then select the Properties...
button.
5. Check the Grouping box. This will show the possible
combinations for redundant pairs.
6. Select the adapter pair you want and then select OK.
Note that the integrated Ethernet controller is located
at PCI bus 1, slot 9.
7. Select Close to exit from the Network setup.
When you restart the server, the failover function will
be in effect.
If a failover occurs, a message is written to the Windows
NT Event Viewer log. If the DMI instrumentation code for
the integrated Ethernet controller is active (PCNET.EXE
was run), a pop-up message is generated also.
Configuring Failover on IntraNetWare
1. Install the redundant NIC adapter according to the
instructions provided with the adapter and in
“Installing or removing adapters” on page 57.
2. Load the device driver by using the following
command:
LOAD
d
:\
path
\PCNTNW.LAN PRIMARY=
x
SECONDARY=
y
where
d and path are the drive and path where the
driver is located, and
x and y are the PCI slot
numbers where the redundant pair is located.
The slot number associated with the integrated
Ethernet controller can vary depending upon the
42
Netfinity Server HMM
Summary of Contents for 865951Y - Netfinity 5000 - 51Y
Page 2: ......
Page 8: ...vi Netfinity Server HMM...
Page 12: ...Keyboards 172 Power cords 174 4 Netfinity Server HMM...
Page 195: ...Related service information 187...
Page 196: ...188 Netfinity Server HMM...
Page 197: ...Related service information 189...
Page 198: ...190 Netfinity Server HMM...
Page 208: ...200 Netfinity Server HMM...
Page 209: ...Related service information 201...
Page 219: ......
Page 220: ...IBM Part Number 10K2657 Printed in U S A S1 L 9837 4...