Error symptoms
Error Symptom
FRU/Action
CD is not working properly.
1. Clean the CD
2. Clean the optical-head
lens.
3. CD-ROM Drive
CD-ROM drive tray is not
working.
(The server must be
powered-on.) If the server
is on and the tray does not
eject,
1. Insert the end of a
paper clip into the
manual tray-release
opening.
2. CD-ROM Drive
CD-ROM drive is not
recognized.
1. Run
Configuration/Setup,
enabled primary IDE
channel.
2. Check cables and
jumpers.
3. Check for correct
device driver.
Diskette drive in-use light
stays on, or the system
bypasses the diskette drive.
If there is a diskette in the
drive, verify that:
1. The diskette drive is
enabled in the
Configuration/Setup
utility programs.
2. The diskette is good
and not damaged.
(Try another diskette if
you have one.)
3. The diskette is inserted
correctly in the drive.
4. The diskette contains
the necessary files to
start the server.
5. The software program
is OK.
If the diskette drive in-use
light stays on, or the system
continues to bypass the
diskette drive, replace the
diskette drive.
Monitor problems (general)
Some IBM monitors have
their own self-tests. If you
suspect a problem with the
monitor, refer to the
information that comes with
the monitor for adjusting
and testing instructions.
1. Monitor
2. Display
Adapter/System Board
Netfinity 5000 - Type 8659
159
Summary of Contents for 865951Y - Netfinity 5000 - 51Y
Page 2: ......
Page 8: ...vi Netfinity Server HMM...
Page 12: ...Keyboards 172 Power cords 174 4 Netfinity Server HMM...
Page 195: ...Related service information 187...
Page 196: ...188 Netfinity Server HMM...
Page 197: ...Related service information 189...
Page 198: ...190 Netfinity Server HMM...
Page 208: ...200 Netfinity Server HMM...
Page 209: ...Related service information 201...
Page 219: ......
Page 220: ...IBM Part Number 10K2657 Printed in U S A S1 L 9837 4...