Error Code/Symptom
FRU/Action
201-XXX-001
(Failed Memory test)
1. DIMM Location J15
201-XXX-002
(Failed Memory test)
1. DIMM Location J16
201-XXX-003
(Failed Memory test)
1. DIMM Location J17
201-XXX-004
(Failed Memory test)
1. DIMM Location J22
201-XXX-999
(Multiple DIMM failure, see
error text.)
1. See error text for
failing DIMMs
202-XXX-001
(Failed System Cache test)
1. Microprocessor
202-XXX-002
(Failed System Cache test
on Optional Microprocessor)
1. Optional
Microprocessor
206-XXX-000
(Failed Diskette Drive test)
1. Diskette Drive cable
2. Diskette Drive
215-XXX-000
(Failed IDE CD-ROM test)
1. CD-ROM Drive
Cables
2. CD-ROM Drive
3. System Board
217-XXX-000
(Failed BIOS Fixed Disk
test)
Note
If RAID is configured,
the fixed disk number
refers to the RAID
logical drive.
1. Fixed Disk 1
217-XXX-001
(Failed BIOS Fixed Disk
test)
Note
If RAID is configured,
the fixed disk number
refers to the RAID
logical drive.
1. Fixed Disk 2
217-XXX-002
(Failed BIOS Fixed Disk
test)
Note
If RAID is configured,
the fixed disk number
refers to the RAID
logical drive.
1. Fixed Disk 3
Netfinity 5000 - Type 8659
157
Summary of Contents for 865951Y - Netfinity 5000 - 51Y
Page 2: ......
Page 8: ...vi Netfinity Server HMM...
Page 12: ...Keyboards 172 Power cords 174 4 Netfinity Server HMM...
Page 195: ...Related service information 187...
Page 196: ...188 Netfinity Server HMM...
Page 197: ...Related service information 189...
Page 198: ...190 Netfinity Server HMM...
Page 208: ...200 Netfinity Server HMM...
Page 209: ...Related service information 201...
Page 219: ......
Page 220: ...IBM Part Number 10K2657 Printed in U S A S1 L 9837 4...