To install a drive in a hot-swap bay:
1. Remove the filler panel
.1/
from one of the empty
hot-swap bays by inserting your finger into the
depression at the top of the filler panel (tower model)
or left side of the filler panel (rack model) and pulling
it away from the server.
Attention
To maintain proper system cooling, do not
operate the Netfinity 5000 for more than two
minutes without either a drive or a filler panel
installed for each bay.
.1/
Filler panel
.2/
Drive
.3/
Tray handle
2. Install the hard disk drive
.2/
in the hot-swap bay.
a. Ensure the tray handle
.3/
is open (that is,
perpendicular to the drive).
b. Align the drive-tray assembly so that it engages
the guide rails in the bay.
c. Gently push the drive-tray assembly into the bay
until the drive connects to the backplane.
d. Push the tray handle toward the drive until the
handle locks.
3. Check the hard disk drive status indicators to verify
that the hard disk drives are operating properly. See
“Front panel indicators” on page 85 for details.
Notes
1. There are no termination requirements for
any SCSI hard disk drives installed in the
hard drive bays. Termination is achieved
through the DASD backplane.
2. If the Netfinity 5000 has a RAID adapter or
controller, you might want to reconfigure the
disk arrays after installing hard disk drives;
consult the documentation that came with
the adapter or controller.
Netfinity 5000 - Type 8659
73
Summary of Contents for 865951Y - Netfinity 5000 - 51Y
Page 2: ......
Page 8: ...vi Netfinity Server HMM...
Page 12: ...Keyboards 172 Power cords 174 4 Netfinity Server HMM...
Page 195: ...Related service information 187...
Page 196: ...188 Netfinity Server HMM...
Page 197: ...Related service information 189...
Page 198: ...190 Netfinity Server HMM...
Page 208: ...200 Netfinity Server HMM...
Page 209: ...Related service information 201...
Page 219: ......
Page 220: ...IBM Part Number 10K2657 Printed in U S A S1 L 9837 4...