Error Code/Symptom
FRU/Action
1806
(PCI to PCI Bridge error)
1. Run
Configuration/Setup
2. Move the failing
adapter to slot 1 or 2
3. Failing Adapter
4. System Board
1807, 1808, 1810
(General PCI error)
1. Remove Failing PCI
Card
2. System Board
1962
(Drive does not contain a
valid boot sector)
1. Verify a bootable
operating system is
installed
2. Run Diagnostics
3. Hard Disk Drive Cable
4. System Board
5. Hard Disk Drive
2400
(Video controller test failure)
1. Video Adapter
(if installed)
2. System Board
2462
(Video memory
configuration error)
1. Video Adapter
(if installed)
2. System Board
5962
(IDE CD-ROM configuration
error)
1. Run
Configuration/Setup
2. CD-ROM Drive
3. Battery
8603
(Pointing Device Error)
1. Pointing Device
2. System Board
0001200
(Machine check architecture
error)
1. Processor
2. Optional Processor
000120P0,
000120P1,000120P2,000120PF
(Processor cache error)
1. Failing Processor
01295085
(ECC checking hardware
test error)
1. Processor
I9990301
(Fixed boot sector error, no
operating system installed)
1. Run
Configuration/Setup
for correct startup
2. Verify operating
system installed
I9990305
(Fixed boot sector error, no
operating system installed)
1. Install operating
system to hard disk
drive.
I9990650
(AC power has been
restored)
1. Check cable
2. Check for interruption
of power supply
3. Power Cable
164
Netfinity Server HMM
Summary of Contents for 865951Y - Netfinity 5000 - 51Y
Page 2: ......
Page 8: ...vi Netfinity Server HMM...
Page 12: ...Keyboards 172 Power cords 174 4 Netfinity Server HMM...
Page 195: ...Related service information 187...
Page 196: ...188 Netfinity Server HMM...
Page 197: ...Related service information 189...
Page 198: ...190 Netfinity Server HMM...
Page 208: ...200 Netfinity Server HMM...
Page 209: ...Related service information 201...
Page 219: ......
Page 220: ...IBM Part Number 10K2657 Printed in U S A S1 L 9837 4...