Failover for redundant Ethernet
The Netfinity 5000 has an integrated Ethernet controller.
The IBM Netfinity 10/100 Fault Tolerant Adapter is an
optional redundant network interface card (NIC adapter)
that you can install in the server. If you install this NIC
adapter and connect it to the same logical segment as the
primary Ethernet controller, you can configure the server to
support a
failover function. You can configure either the
integrated Ethernet controller or the NIC adapter as the
primary Ethernet controller. In failover mode, if the primary
Ethernet controller detects a link failure, all Ethernet traffic
associated with it is switched to the redundant (secondary)
controller. This switching occurs without any user
intervention. Applications with active sessions do not
experience any data loss. When the primary link is
restored to an operational state, the Ethernet traffic
automatically switches back to the primary Ethernet
controller.
Notes
1. Only one controller in the redundant pair is active
at any given time. For example, if the primary
Ethernet controller is active, then the secondary
Ethernet controller cannot be used for any other
network operation.
2. The operating system determines the maximum
number of IBM Netfinity 10/100 Fault Tolerant
Adapters that you can install in the server. See
the documentation that comes with the adapter
for more information.
The failover feature currently is supported by OS/2,
Windows NT, and IntraNetWare. The setup required for
each operating system follows.
Configuring Failover on OS/2
1. Install the redundant NIC adapter according to the
instructions provided with the adapter and in
“Installing or removing adapters” on page 57.
2. Use the ServerGuide CDs to install the AMD PCNet
Ethernet Family adapter device driver.
3. Using the MPTS utility program, select the driver from
the list and select the Edit button.
Note
Only one driver instance needs to be loaded for
each redundant pair of Ethernet controllers.
4. Change the PermaNet Server Feature keyword to
TRUE and specify the Primary and Standby slots that
contain the redundant pair. Refer to “System board
illustration” on page 142 for the locations and slot
Netfinity 5000 - Type 8659
41
Summary of Contents for 865951Y - Netfinity 5000 - 51Y
Page 2: ......
Page 8: ...vi Netfinity Server HMM...
Page 12: ...Keyboards 172 Power cords 174 4 Netfinity Server HMM...
Page 195: ...Related service information 187...
Page 196: ...188 Netfinity Server HMM...
Page 197: ...Related service information 189...
Page 198: ...190 Netfinity Server HMM...
Page 208: ...200 Netfinity Server HMM...
Page 209: ...Related service information 201...
Page 219: ......
Page 220: ...IBM Part Number 10K2657 Printed in U S A S1 L 9837 4...