SCSI error codes
Error Code
FRU/Action
All SCSI Errors
One or more of the following
might be causing the
problem:
A failing SCSI device
(adapter, drive,
controller)
An improper SCSI
configuration or SCSI
termination jumper
setting
Duplicate SCSI IDs in
the same SCSI chain
A missing or improperly
installed SCSI
terminator
A defective SCSI
terminator
An improperly installed
cable
A defective cable
1. External SCSI
devices must be
powered-on before
you power-on the
server.
2. The cables for all
external SCSI devices
are connected
correctly.
3. If you have attached
an external SCSI
device to the server,
make sure the external
SCSI termination is set
to automatic.
4. The last device in each
SCSI chain is
terminated correctly.
5. The SCSI devices are
configured correctly.
Undetermined problems
You are here because the diagnostic tests did not identify
the failure, the Devices List is incorrect, or the system is
inoperative.
Notes
1. If you suspect a software mismatch is causing
failures (solid or intermittent), be sure to see
“Resolving resource conflicts” on page 50.
2. A corrupt CMOS can cause undetermined
problems.
Check the LEDs on all the power supplies. If the LEDs
indicate the power supplies are working correctly, return
here and do the following:
1. Power-off the computer.
2. Be sure the system is cabled correctly.
3. Remove or disconnect the following (one at a time)
until you find the failure (power-on the computer and
reconfigure each time).
Any external devices
Surge suppressor device (on the computer)
Modem, printer, mouse, or non-IBM devices
Each adapter
Drives
Memory-Module Kits (Minimum requirement = 1
bank of 64 MB DIMMs)
Secondary microprocessor VRM, if installed
Netfinity 5000 - Type 8659
165
Summary of Contents for 865951Y - Netfinity 5000 - 51Y
Page 2: ......
Page 8: ...vi Netfinity Server HMM...
Page 12: ...Keyboards 172 Power cords 174 4 Netfinity Server HMM...
Page 195: ...Related service information 187...
Page 196: ...188 Netfinity Server HMM...
Page 197: ...Related service information 189...
Page 198: ...190 Netfinity Server HMM...
Page 208: ...200 Netfinity Server HMM...
Page 209: ...Related service information 201...
Page 219: ......
Page 220: ...IBM Part Number 10K2657 Printed in U S A S1 L 9837 4...