Diagnostic tools
Server problems can be caused by the hardware, the
software, or a user error. An example of a user error is
pressing the wrong key on the keyboard.
You can check the hardware by using the diagnostic test
programs and the information in this section.
Note
When you run the diagnostic test programs, a single
problem can cause several error messages to occur.
When this happens, work to correct the cause of the
first error message. After the cause is corrected, the
other error messages probably will not occur the next
time you run the tests.
If the hardware is OK and you have not made an error,
you might have a software problem. If you suspect that
you have a software problem, refer to the information that
comes with that software package.
Diagnostic tools overview
The following tools are available to help identify and
resolve hardware-related problems:
LEDs on the system board and power supplies
Diagnostic test programs
Power-on self-test (POST)
POST beep codes
Error messages
Troubleshooting charts
Option diskettes
Diagnostic LEDs:
When a system error occurs, the
relevant LEDs on the system board are lighted to identify
where the errors are (see “System board LEDs” on
page 142). When you see the System Error LED
illuminated on the operator LED (status) panel on the front
of the server, check the LEDs on the power supplies and
at any Ethernet adapters, then open the cover and see
which LEDs are illuminated on the system board.
Diagnostic test programs:
The server
diagnostics test programs are stored in nonvolatile
random-access memory (NVRAM) on the system board.
These programs are the primary method of testing the
system board, memory, and other standard features of the
Netfinity 5000. You can also use them to test some
external devices.
Also, if you cannot determine whether a problem is caused
by the hardware or by the software, you can run the test
programs to confirm that the hardware is working properly.
8
Netfinity Server HMM
Summary of Contents for 865951Y - Netfinity 5000 - 51Y
Page 2: ......
Page 8: ...vi Netfinity Server HMM...
Page 12: ...Keyboards 172 Power cords 174 4 Netfinity Server HMM...
Page 195: ...Related service information 187...
Page 196: ...188 Netfinity Server HMM...
Page 197: ...Related service information 189...
Page 198: ...190 Netfinity Server HMM...
Page 208: ...200 Netfinity Server HMM...
Page 209: ...Related service information 201...
Page 219: ......
Page 220: ...IBM Part Number 10K2657 Printed in U S A S1 L 9837 4...