Table 140. Functions for supported SAS cables (continued)
Cable type
Function
X cable
This cable is used to connect two SAS adapters to a disk
expansion drawer in a RAID configuration. The cable
must be routed along the right side of the rack frame (as
viewed from the rear) when connecting to a disk
expansion drawer.
AE1 cable
This 4 m (13.1 ft) SAS cable connects a PCIe3 SAS
adapter to a SAS tape drive or DVD I/O enclosure. The
AE cable has two connectors, one mini-SAS HD narrow
connector and one mini-SAS connector. The mini-SAS
HD Narrow connector attaches to a PCIe3 SAS adapter.
The mini-SAS connector attaches to a SAS tape drive or
DVD enclosure.
YE1 cable
This 3 m (9.8 ft) SAS cable connects a PCIe3 SAS adapter
to one or two SAS tape drives in an I/O enclosure. The
YE1 cable has three connectors, one mini-SAS HD (High
Density) narrow connector and two mini-SAS connectors.
The Mini-SAS HD Narrow connector attaches to a PCIe3
SAS adapter. Each mini-SAS connector attaches to a
different SAS tape drive.
AS cable
This 3 m (9.8 ft) SAS cable is used to attach a DCS3700 to
PCIe3 LP RAID SAS adapter.
The following table contains specific information about each supported SAS cable for PCIe2 and prior
SAS adapters.
Table 141. Supported SAS cables for PCIe2 and prior SAS adapters
Name
Length
IBM part number
Feature code
SAS 4x AI cable
1 m (3.2 ft)
44V4041
3679
SAS 4x AE cable
3 m (9.8 ft)
44V4163
3684
6 m (19.6 ft)
44V4164
3685
SAS 4x AT cable
0.6 m (1.9 ft)
44V5132
3688
SAS 4x EE cable
1 m (3.2 ft)
44V4147
3652
3 m (9.8 ft)
44V4148
3653
6 m (19.6 ft)
44V4149
3654
HD SAS 4x AT cable
0.6 m (1.9 ft)
74Y6260
3689
HD SAS AA cable
0.6 m (1.9 ft)
00J0094
5918
1.5 m (4.9 ft)
74Y9029
5917
3 m (9.8 ft)
74Y9030
5915
6 m (19.6 ft)
74Y9031
5916
HD SAS EX cable
1.5 m (4.9 ft)
00E5648
5926
3 m (9.8 ft)
74Y9033
3675
6 m (19.6 ft)
74Y9034
3680
HD SAS X cable
3 m (9.8 ft)
74Y9041
3454
6 m (19.6 ft)
74Y9042
3455
10 m (32.8 ft)
74Y9043
3456
15 m (49.2 ft)
74Y9044
3458
124
Site and hardware planning
Summary of Contents for 8408-44E
Page 1: ...Power Systems Site and hardware planning IBM...
Page 2: ......
Page 3: ...Power Systems Site and hardware planning IBM...
Page 16: ...xiv Site and hardware planning...
Page 18: ...2 Site and hardware planning...
Page 22: ...6 Site and hardware planning...
Page 51: ...Figure 19 Model 0555 and 7014 S25 plan view Site and hardware planning 35...
Page 192: ...176 Site and hardware planning...
Page 204: ...188 Site and hardware planning...
Page 205: ......
Page 206: ...IBM Printed in USA...