Table 93. Dimensions
Width
Depth
Height
Weight
216 mm (8.5 in.)
540 mm (21.25 in.)
438 mm (17.25 in)
19.6 - 21.4 kg (43 - 47 lb)
Table 94. Electrical
Electrical characteristics
Properties
Maximum measured power
523 W
Maximum kVA
.55
Frequency
50 or 60 Hz
Maximum thermal output
1784 BTU/hr
Input voltage low range
100 - 127 V ac
Input voltage high range
200 - 240 V ac
Table 95. Environment requirements
Environment
System requirements
Altitude
Recommended operating temperature 10°C - 35°C (50°F - 95°F)
0 - 914.4 m (0 - 3000 ft)
10°C - 32°C (50°F - 89.6°F)
914.4 - 2133.6 m (3000 - 7000 ft)
Nonoperating temperature
10°C - 43°C (50°F - 109.4°F)
2133.6 m (7000 ft)
Maximum altitude
NA
2133.6 m (7000 ft)
Shipping temperature
-40°C to 60°C (-40°F to 140°F)
Operating humidity
8% - 80%
Nonoperating humidity
8% - 80%
7042-CR7 Hardware Management Console specifications
Hardware specifications provide detailed information about your Hardware Management Console
(HMC), including dimensions, electrical, environmental requirements, and noise emissions.
The HMC controls managed systems, including the management of logical partitions and the use of
capacity on demand (CoD). By using service applications, the HMC communicates with managed
systems to detect, consolidate, and send information to IBM for analysis. The HMC provides service
technicians with diagnostic information for systems that can operate in a multiple-partitioned
environment.
Use the following specifications to plan for your HMC.
Table 96. Dimensions
Width
Depth
Height
Weight (maximum
configuration)
429 mm (16.9 in.)
734 mm (28.9 in.)
43 mm (1.7 in.)
16.4 kg (36.16 lb)
Table 97. Electrical requirements
Electrical characteristics
Properties
Maximum measured power
351 W
Maximum thermal output
1198 Btu/hr
Input voltage low range
100 - 127 V ac
Input voltage high range
200 - 240 V ac
78
Site and hardware planning
Summary of Contents for 8408-44E
Page 1: ...Power Systems Site and hardware planning IBM...
Page 2: ......
Page 3: ...Power Systems Site and hardware planning IBM...
Page 16: ...xiv Site and hardware planning...
Page 18: ...2 Site and hardware planning...
Page 22: ...6 Site and hardware planning...
Page 51: ...Figure 19 Model 0555 and 7014 S25 plan view Site and hardware planning 35...
Page 192: ...176 Site and hardware planning...
Page 204: ...188 Site and hardware planning...
Page 205: ......
Page 206: ...IBM Printed in USA...