Table 120. Environmental and acoustical requirements (continued)
Environment/Acoustical
Operating
Storage
Relative humidity range
(non-condensing)
10% - 90% RH
10% - 90% RH
Maximum altitude
1800 m (6000 ft)
12190 m (40000 ft)
Heat dissipation
1127 Btu/hr
Acoustic noise
Less than 65 dB
G8316R RackSwitch specification sheet
Hardware specifications provide detailed information for your IBM BNT RackSwitch, including
dimensions, electrical, power, temperature, environment, and service clearances.
Table 121. Dimensions
Height
Width
Depth
Weight (maximum)
43.7 mm (1.72 in.)
439 mm (17.3 in.)
483 mm (19.0 in.)
9.98 kg (22.0 lb)
Table 122. Electrical
Electrical characteristics
Properties
Power requirements
400 W
Voltage
100 - 240 V ac
Frequency
50 - 60 Hz
Maximum thermal output
1365 Btu/hr
Phase
1
kVA
0.408
Table 123. Environmental requirements
Environment
Operating
Airflow direction
Rear-to-front
Temperature, ambient operating
0°C - 40°C (32°F - 104°F)
Relative humidity range (non-condensing)
10% - 90% RH
Maximum altitude
3050 m (10000 ft)
Heat dissipation
1100 Btu/hr
Rack installation specifications for racks not purchased from IBM
Learn the requirements and specifications for installing IBM systems into racks that were not purchased
from IBM.
This topic provides requirements and specifications for 19-inch racks. These requirements and
specifications are provided as an aid to help you understand the requirements to install IBM systems into
racks. It is your responsibility, working with your rack manufacturer, to ensure that the rack chosen
meets the requirements and specifications that are listed here. Mechanical drawings of the rack, if
available from the manufacturer, are recommended for comparison against the requirements and
specifications.
IBM maintenance services and installation planning services do not cover verification of non-IBM racks
for compliance to Power Systems
™
rack specifications. IBM offers racks for IBM products that are tested
and verified by IBM development labs to comply with applicable safety and regulatory requirements.
86
Site and hardware planning
Summary of Contents for 8408-44E
Page 1: ...Power Systems Site and hardware planning IBM...
Page 2: ......
Page 3: ...Power Systems Site and hardware planning IBM...
Page 16: ...xiv Site and hardware planning...
Page 18: ...2 Site and hardware planning...
Page 22: ...6 Site and hardware planning...
Page 51: ...Figure 19 Model 0555 and 7014 S25 plan view Site and hardware planning 35...
Page 192: ...176 Site and hardware planning...
Page 204: ...188 Site and hardware planning...
Page 205: ......
Page 206: ...IBM Printed in USA...