Table 39. IMM error messages (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
If an action step is preceded by “(Trained technician only)”, that step must be performed only by a trained
technician.
80010b01-1404ffff
Sensor DIMM CD VR
Temp going high
(upper
non-recoverable) has
asserted.
Error
An upper
non-recoverable
sensor going high
has asserted.
Check the server airflow. Make sure
that nothing is blocking the air from
coming into or preventing the air from
exiting the server.
80010701-1405ffff
Sensor DIMM EF VR
Temp going high
(upper non-critical)
has asserted.
Warning An upper
non-critical sensor
going high has
asserted.
1.
Reduce the ambient temperature.
2.
Check the server airflow. Make sure
that nothing is blocking the air
from coming into or preventing the
air from exiting the server.
80010901-1405ffff
Sensor DIMM EF VR
Temp going high
(upper critical) has
asserted.
Error
An upper critical
sensor going high
has asserted.
1.
Reduce the ambient temperature.
2.
Check the server airflow. Make sure
that nothing is blocking the air
from coming into or preventing the
air from exiting the server.
80010b01-1405ffff
Sensor DIMM EF VR
Temp going high
(upper
non-recoverable) has
asserted.
Error
An upper
non-recoverable
sensor going high
has asserted.
Check the server airflow. Make sure
that nothing is blocking the air from
coming into or preventing the air from
exiting the server.
80010701-1406ffff
Sensor DIMM GH
VR Temp going high
(upper non-critical)
has asserted.
Warning An upper
non-critical sensor
going high has
asserted.
1.
Reduce the ambient temperature.
2.
Check the server airflow. Make sure
that nothing is blocking the air
from coming into or preventing the
air from exiting the server.
80010901-1406ffff
Sensor DIMM GH
VR Temp going high
(upper critical) has
asserted.
Error
An upper critical
sensor going high
has asserted.
1.
Reduce the ambient temperature.
2.
Check the server airflow. Make sure
that nothing is blocking the air
from coming into or preventing the
air from exiting the server.
80010b01-1406ffff
Sensor DIMM GH
VR Temp going high
(upper
non-recoverable) has
asserted.
Error
An upper
non-recoverable
sensor going high
has asserted.
Check the server airflow. Make sure
that nothing is blocking the air from
coming into or preventing the air from
exiting the server.
80010701-2d01ffff
Numeric sensor PCH
Temp going high
(upper non-critical)
has asserted.
Warning An upper
non-critical sensor
going high has
asserted.
1.
Reduce the ambient temperature.
2.
Check the server airflow. Make sure
that nothing is blocking the air
from coming into or preventing the
air from exiting the server.
80010901-2d01ffff
Numeric sensor PCH
Temp going high
(upper critical) has
asserted.
Error
An upper critical
sensor going high
has asserted.
1.
Reduce the ambient temperature.
2.
Check the server airflow. Make sure
that nothing is blocking the air
from coming into or preventing the
air from exiting the server.
Appendix C. Integrated management module II (IMM2) error messages
401
Summary of Contents for 7383
Page 1: ...System x3500 M4 Type 7383 Installation and Service Guide ...
Page 2: ......
Page 3: ...System x3500 M4 Type 7383 Installation and Service Guide ...
Page 8: ...vi System x3500 M4 Type 7383 Installation and Service Guide ...
Page 42: ...24 System x3500 M4 Type 7383 Installation and Service Guide ...
Page 200: ...182 System x3500 M4 Type 7383 Installation and Service Guide ...
Page 360: ...342 System x3500 M4 Type 7383 Installation and Service Guide ...
Page 416: ...398 System x3500 M4 Type 7383 Installation and Service Guide ...
Page 470: ...452 System x3500 M4 Type 7383 Installation and Service Guide ...
Page 479: ...Taiwan Class A compliance statement Notices 461 ...
Page 480: ...462 System x3500 M4 Type 7383 Installation and Service Guide ...
Page 487: ......
Page 488: ... Part Number 46W8192 Printed in USA 1P P N 46W8192 ...