Table 39. IMM error messages (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
If an action step is preceded by “(Trained technician only)”, that step must be performed only by a trained
technician.
806f000f-2201ffff
The System %1
encountered a POST
Error. (%1 =
CIM_ComputerSystem.
ElementName)
Error
The System
encountered a
firmware error.
(Sensor = Firmware
Error)
1.
Make sure the server meets the
minimum configuration to start
(see Power-supply LEDs).
2.
Update the server firmware on the
primary page.
Important:
Some cluster solutions
require specific code levels or
coordinated code updates. If the
device is part of a cluster solution,
verify that the latest level of code is
supported for the cluster solution
before you update the code.
3.
(Trained technician only) Replace
the system board.
806f010f-2201ffff
The System %1
encountered a POST
Hang. (%1 =
CIM_ComputerSystem.ElementName)
Error
The System
encountered a
firmware hang.
(Sensor = Firmware
Error)
1.
Make sure the server meets the
minimum configuration to start
(see Power-supply LEDs).
2.
Update the server firmware on the
primary page.
Important:
Some cluster solutions
require specific code levels or
coordinated code updates. If the
device is part of a cluster solution,
verify that the latest level of code is
supported for the cluster solution
before you update the code.
3.
(Trained technician only) Replace
the system board.
806f052b-2101ffff
IMM2 FW Failover
has been detected.
Error
Invalid or
unsupported
firmware or
software was
detected.
1.
Make sure the server meets the
minimum configuration to start
(see Power-supply LEDs).
2.
Update the server firmware to the
latest level (see Updating the
firmware).
Important:
Some cluster solutions
require specific code levels or
coordinated code updates. If the
device is part of a cluster solution,
verify that the latest level of code is
supported for the cluster solution
before you update the code.
3.
Remove components one at a time,
restarting the server each time, to
see if the problem goes away.
4.
If the problem remains, (trained
technician only) replace the system
board (see Removing the system
board and Installing the system
board).
436
System x3500 M4 Type 7383: Installation and Service Guide
Summary of Contents for 7383
Page 1: ...System x3500 M4 Type 7383 Installation and Service Guide ...
Page 2: ......
Page 3: ...System x3500 M4 Type 7383 Installation and Service Guide ...
Page 8: ...vi System x3500 M4 Type 7383 Installation and Service Guide ...
Page 42: ...24 System x3500 M4 Type 7383 Installation and Service Guide ...
Page 200: ...182 System x3500 M4 Type 7383 Installation and Service Guide ...
Page 360: ...342 System x3500 M4 Type 7383 Installation and Service Guide ...
Page 416: ...398 System x3500 M4 Type 7383 Installation and Service Guide ...
Page 470: ...452 System x3500 M4 Type 7383 Installation and Service Guide ...
Page 479: ...Taiwan Class A compliance statement Notices 461 ...
Page 480: ...462 System x3500 M4 Type 7383 Installation and Service Guide ...
Page 487: ......
Page 488: ... Part Number 46W8192 Printed in USA 1P P N 46W8192 ...