Table 39. IMM error messages (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
If an action step is preceded by “(Trained technician only)”, that step must be performed only by a trained
technician.
806f0323-2101ffff
Power cycle of
system
[ComputerSystemElementName]
initiated by
watchdog IPMI
Watchdog.
Info
The IPMI
watchdog timer
has expired. The
compute node has
been powered off
and powered on.
No action; information only.
806f0823-2101ffff
Watchdog Timer
interrupt occurred for
[WatchdogElementName].
Info
The IPMI
watchdog timer
has expired. A
watchdog interrupt
has occurred.
No action; information only.
81030012-2301ffff
OS RealTime Mod
state has deasserted.
Info
Indicate whether
the system
management
firmware is
working in the
state to support the
realtime OS.
No action; information only.
80070219-0701ffff
Sensor SysBrd Fault
has transitioned to
critical.
Error
A sensor has
changed to Critical
state from a less
severe state.
1.
Check the system-event log.
2.
Check for an error LED on the
system board.
3.
Replace any failing device.
4.
Check for a server firmware update.
Important:
Some cluster solutions
require specific code levels or
coordinated code updates. If the
device is part of a cluster solution,
verify that the latest level of code is
supported for the cluster solution
before you update the code.
5.
(Trained technician only) Replace
the system board (see Removing the
system board and Installing the
system board).
806f020f-2201ffff
The System %1
encountered a POST
Progress. (%1 =
CIM_ComputerSystem.ElementName)
Info
A POST progress
has been detected.
(Sensor = Progress)
No action; information only.
806f0312-2201ffff
Entry to aux log has
asserted.
Info
Entry to aux log
has been detected.
No action; information only.
80080128-2101ffff
Low security jumper
presence has
asserted.
Info
The low security
jumper has been
detected.
No action; information only.
8008010f-2101ffff
Physical presence
jumper presence has
asserted.
Info
The physical
presence jumper
has been detected.
No action; information only.
81030006-2101ffff
Sig verify fail has
deasserted.
Info
The sig verify fail
has deasserted.
No action; information only.
440
System x3500 M4 Type 7383: Installation and Service Guide
Summary of Contents for 7383
Page 1: ...System x3500 M4 Type 7383 Installation and Service Guide ...
Page 2: ......
Page 3: ...System x3500 M4 Type 7383 Installation and Service Guide ...
Page 8: ...vi System x3500 M4 Type 7383 Installation and Service Guide ...
Page 42: ...24 System x3500 M4 Type 7383 Installation and Service Guide ...
Page 200: ...182 System x3500 M4 Type 7383 Installation and Service Guide ...
Page 360: ...342 System x3500 M4 Type 7383 Installation and Service Guide ...
Page 416: ...398 System x3500 M4 Type 7383 Installation and Service Guide ...
Page 470: ...452 System x3500 M4 Type 7383 Installation and Service Guide ...
Page 479: ...Taiwan Class A compliance statement Notices 461 ...
Page 480: ...462 System x3500 M4 Type 7383 Installation and Service Guide ...
Page 487: ......
Page 488: ... Part Number 46W8192 Printed in USA 1P P N 46W8192 ...