Table 39. IMM error messages (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
If an action step is preceded by “(Trained technician only)”, that step must be performed only by a trained
technician.
80030108-1301ffff
Sensor PS Heavy
Load has asserted.
Info
The system is
consuming more
power than the
power supply or
supplies are rated
for. The system
will throttle to
avoid shutting
down due to a
power supply
over-current
condition.
1.
Reduce the total power
consumption by removing newly
added or unused options like hard
drives or adapters.
2.
Add an additional power supply to
any empty power supply bay.
800b0309-1301ffff
Non-
redundant:Sufficient
Resources from
Redundancy
Degraded or Fully
Redundant for Power
Resource has
asserted.
Warning A change to the
sufficiency status
of the power
supply has
happened.
1.
Power load will be handled by
remaining power supply, though
the system may throttle to avoid a
power supply over-current
condition. Check the power supply
LED's, see Power-supply LEDs.
2.
Replace the power supply with
higher rated power.
800b0509-1301ffff
Non-
redundant:Insufficient
Resources for Power
Resource has
asserted.
Error
A change to the
sufficiency status
of the power
supply has
happened.
1.
Power load may be handled by
remaining power supply. The
system will attempt to throttle to
avoid a power supply over-current
condition, but a system shutdown
may happen anyway if the power
load is too great. Check the power
supply LED's, see Power-supply
LEDs.
2.
Reduce the total power
consumption by removing newly
added or unused options like hard
drives or adapters.
3.
Use the IBM Power Configuration
utility to determine current system
power consumption.
4.
Replace the power supply with
higher rated power.
806f0008-0a01ffff
806f0008-0a02ffff
The Power Supply
(Power Supply
n
)
presence has been
detected. (
n
= power
supply number)
Info
Power supply
n
has been added. (
n
= power supply
number)
No action; information only.
806f0009-1301ffff
System board 1 has
been turned off
Info
The compute node
has been powered
off.
No action; information only.
Appendix C. Integrated management module II (IMM2) error messages
405
Summary of Contents for 7383
Page 1: ...System x3500 M4 Type 7383 Installation and Service Guide ...
Page 2: ......
Page 3: ...System x3500 M4 Type 7383 Installation and Service Guide ...
Page 8: ...vi System x3500 M4 Type 7383 Installation and Service Guide ...
Page 42: ...24 System x3500 M4 Type 7383 Installation and Service Guide ...
Page 200: ...182 System x3500 M4 Type 7383 Installation and Service Guide ...
Page 360: ...342 System x3500 M4 Type 7383 Installation and Service Guide ...
Page 416: ...398 System x3500 M4 Type 7383 Installation and Service Guide ...
Page 470: ...452 System x3500 M4 Type 7383 Installation and Service Guide ...
Page 479: ...Taiwan Class A compliance statement Notices 461 ...
Page 480: ...462 System x3500 M4 Type 7383 Installation and Service Guide ...
Page 487: ......
Page 488: ... Part Number 46W8192 Printed in USA 1P P N 46W8192 ...