8-8 User
Parameters
Parameters are displayed and edited.
On the following page, user parameter display examples of the PCON-CY controller are provided.
* The contents will vary depending on each controller. Refer to the operating manual of each controller.
There are 6 screens for user parameters.
Each screen can be changed using the
key.
When changing a parameter, move the cursor to the parameter value to be changed. Input a numeric
value with the ten-key pad and press the Return key.
(To move the cursor, use the
key.)
Restore the controller power after making parameter changes.
In the case of any model which supports the software reset (restart) function (PCON, ACON, SCON, ERC,
RCP2, ERC2), the screen can be moved to the Soft Reset screen by pressing the
key.
(When software has been reset, it is not required to restore the power.)
Note: The changed parameter will become valid by restoring the power or resetting software.
Select “* User Parameter” on the Select Mode
screen and press the Return key.
(Use the
key or key to move the cursor.)
(Note) In the case of the PCON-PL/PO,
ACON-PL/PO, or SCON controller (pulse
train mode), “Edit/Teach (Position)” will be
displayed as “Jog.”