4.4 I/O signals
4-11
4. Operation
4.4 I/O
signals
I/O signal list
ELECYLINDER I/O signals are as follows.
Category Signal
name
Signal
abbreviation
Function overview
Input
Backward
ST0
Turning ON sends it backward.
Turning OFF midway through operation will cause a
gradual stop.
Turning ON when home return is not complete
triggers home return operation.
Turning OFF midway through operation will cause a
gradual stop.
Forward ST1
Turning ON sends it forward.
Turning OFF midway through operation will cause a
gradual stop.
Turning ON when home return is not complete
triggers home return operation.
Turning OFF midway through operation will cause a
gradual stop.
Alarm clear
RES
Turning ON resets the alarm.
Brake release
BKRLS
Inputting 24VDC releases the brake.
Output
Backward complete/
Pressing complete
LS0/PE0
ON when entering the backward end detection range.
ON when pressing operation is complete.
Forward complete/
Pressing complete
LS1/PE1
ON when entering the forward end detection range.
ON when pressing operation is complete.
Alarm
(b-contact)
* ALM
ON in normal conditions.
OFF when an alarm occurs.
Caution
When home return is complete and when it is not,
the [ST0] signal and [ST1] signal have different functions.
Summary of Contents for EC-R6
Page 9: ......
Page 28: ...Intro 19 ...
Page 130: ...1 100 1 Specifications ...
Page 202: ...2 70 2 Installation ...
Page 218: ...3 15 3 Wiring ...
Page 240: ...4 21 4 Operation ...
Page 328: ...9 15 9 External Dimensions ...
Page 336: ...11 3 11 Warranty ...
Page 337: ...Appendix 12 1 Index 12 1 12 2 Revision history 12 7 ELECYLINDER Chapter12 ...
Page 346: ......
Page 347: ......