3.4 Wiring connections (for connectors)
3.5 Wiring connections (for cables)
3-10
3. Wiring
Brake release wiring
For the specification with brake, when installing a forcible brake release switch,
connect wiring to the [B2] connector terminal.
Power capacity of 24VDC ±10%/200mA or higher is required.
Pin
No.
Connector
nameplate
name
Signal
abbreviation
Compatible
wire diameter
Required specifications
B2
Brake release
BKRLS
KIV 0.20mm
2
(AWG24)
24VDC ±10%/200mA or
higher
3.5 Wiring connections (for cables)
Here the wiring connection method with a power I/O cable is introduced.
Power I/O cable
ST0
ST1
RES
LS0/PE0
LS1/PS1
*ALM
Summary of Contents for EC-R6