1.2 Mechanical specifications
1-58
1. S
pecifications
[Actuator Specifications]
[Pressing Force and Current Limit Value]
Caution
The relation of the current limit and the pressing force is a guideline at speed of 20mm/s.
There is some variance in the actual pressing force. The variance increases when the
current value is low.
The current limit value cannot be set outside the 20 to 70% range.
When the approach speed up to the pressing start position is 20mm/s or less, pressing
operation will take place at approach speed. When the pressing speed is 20mm/s or
less, the pressing force will become unstable and failure to operate normally is
possible.