2.7 Installation of high rigidity radial cylinder type
2-54
2. Installatio
n
Body mounting
[When using base through holes]
When fixing the actuator with the base through holes, remove the frame cover before work.
→
For details regarding the position and dimensions, refer to "Chapter 9 External
Dimensions".
There are a reamed hole and an oblong hole for the positioning pins.
Use the reamed hole and oblong hole if mounting reproducibility after detachment is
required.
When fine adjustment of angles, etc. is required, consider using only the reamed hole.
Reamed hole/oblong hole position dimensions
Reference surface
Oblong hole
Reamed hole
Through hole
Tapped mounting hole
Oblong hole
C