![IAI EC-R6 Instruction Manual Download Page 99](http://html.mh-extra.com/html/iai/ec-r6/ec-r6_instruction-manual_603970099.webp)
1.2 Mechanical specifications
1-69
1. S
pecifications
[Lead and Payload
(Energy-Saving: Enabled)
]
Model
Lead
(mm)
Maximum payload
Max. push
force
(N)
Horizontal
(kg)
Vertical
(kg)
EC-RR6SAH -
①
-
②
(
-
③)
20 6
1
56
EC-RR6HAH -
①
-
②
(
-
③)
12
25
4
93
EC-RR6MAH -
①
-
②
(
-
③)
6 40 10 185
EC-RR6LAH -
①
-
②
(
-
③)
3
40
20
370
Legend
①
Stroke
②
Cable length
③
Option
[Stroke and Max. Speed
(Energy-Saving: Enabled)
]
Lead
(mm)
50 to 400
(Every 50mm)
20 640
12
500
6 250
3
125
(Unit:
mm/s)
Caution
The maximum speed may not be achieved when the stroke or movement distance is
short or when acceleration/deceleration is low.
Setting at or below the minimum speed may lead to abnormal noise or unstable speeds.
The minimum speed can be calculated with the equation below.
Minimum speed [mm/s] = ball screw lead [mm/r] ÷ 800 [p/r] × 1000 [1/s]
(mm/r: movement per 1 motor revolution, p/r: pulse per 1 motor revolution)