3.4 Wiring connections (for connectors)
3-7
3. Wiring
PLC wiring
For I/O between the PLC and signals, the signal wiring must be connected to
the connector terminal block.
Connect the to wiring to the connector terminal block while referring to
the connection diagram.
Connect the [B3] connector terminal and the [Backward] output terminal.
Connect the [B4] connector terminal and the [Forward] output terminal.
Connect the [B5] connector terminal and the [Alarm clear] output terminal.
Connect the [A3] connector terminal and the [Backward complete] input terminal.
Connect the [A4] connector terminal and the [Forward complete] input terminal.
Connect the [A5] connector terminal and the [Alarm] input terminal.
Pin
No.
Connector
nameplate
name
Signal
abbreviation
Compatible
wire diameter
Function overview
B3
Backward ST0
KIV 0.20mm
2
(AWG24)
Backward command
B4
Forward ST1
Forward
command
B5
Alarm clear
RES
Alarm clear
A3
Backward
complete
LS0/PE0
Backward complete/
pressing complete
A4
Forward
complete
LS1/PE1
Forward complete/pressing
complete
A5
Alarm
* ALM
Alarm detection (b-contact)
PLC connection diagram
3
4
5
6
7
8
PLC
Process the terminals
in accordance with
PLC specifications
in order to conduct
wiring.
Power I/O connector
to
3
8
3
8
Before starting connector wiring,
check the details on pages 3-8 to 9
A5 A4
A3
B5 B4 B3
Summary of Contents for EC-R6
Page 9: ......
Page 28: ...Intro 19 ...
Page 130: ...1 100 1 Specifications ...
Page 202: ...2 70 2 Installation ...
Page 218: ...3 15 3 Wiring ...
Page 240: ...4 21 4 Operation ...
Page 328: ...9 15 9 External Dimensions ...
Page 336: ...11 3 11 Warranty ...
Page 337: ...Appendix 12 1 Index 12 1 12 2 Revision history 12 7 ELECYLINDER Chapter12 ...
Page 346: ......
Page 347: ......