User Manual of DS-91/90HFI-ST/RT/XT & DS-81/80HFI-ST & 91/90/81HWI-ST Series DVR
224
14.4
Configuring More Settings
Steps:
1.
Enter the General Settings interface.
Menu > Configuration > General
2.
Click the
More Settings
tab to enter the More Settings interface.
Figure 14. 5
More Settings Interface
3.
Configure the following settings:
•
Device Name:
Edit the name of device.
•
Device No.:
Edit the serial number of device. The Device No. can be set in the range of 1~255, and
the default No. is 255.
•
CVBS Output Brightness:
Adjust the video output brightness.
•
Operation Timeout:
Set timeout time for menu inactivity. E.g., when the timeout time is set to
5
Minutes
, then the system will exit from the current operation menu to live view screen after 5
minutes of menu inactivity.
•
Menu Output Mode:
Set the menu output mode as Auto, HDMI, VGA or Main CVBS. E.g.,
when VGA is selected and VGA output interface is connected, then the menu will be displayed on
VGA monitor.
Note:
For DS-9100/9000/8100HWI-ST series, Auto HDMI/VGA and Main CVBS are selectable
for Menu Output Mode.
4.
Click