User Manual of DS-91/90HFI-ST/RT/XT & DS-81/80HFI-ST & 91/90/81HWI-ST Series DVR
173
Figure 10. 20
Virtual Disk Interface
3.
Click Array tab to back to the Array Settings interface and click
to configure the array rebuild.
Note:
At least one available physical disk should exist for rebuilding the array.
Figure 10. 21
Rebuild Array Interface
4.
Select the available physical disk and click
to confirm to rebuild the array.
5.
The “Do not unplug the physical disk when it is under rebuilding” message box pops up. Click
to start rebuilding.
6.
You can enter the Array Settings interface and Virtual Disk interface to view the rebuilding status.
7.
After rebuilding successfully, the array and virtual disk will restore to Functional.
Note:
It is recommended to enable the
Auto-rebuild
function and set the hot spare disk for automatically rebuilding
the array.