7 – Troubleshooting
Tr
oubleshoo
ti
ng
Hydraulic fluid
Low pressure
The most common causes of low hydraulic fluid are a leak from a fitting or a hose in the hydraulic system and loss of
hydraulic fluid during routine maintenance. A float switch in the hydraulic fluid tank triggers an alarm when the hydraulic
fluid level is too low.
If the hydraulic fluid pressure is low, take these actions.
Make sure that the cut pressure is set correctly. Refer to page 55 for instructions.
Make sure that the pump is not in pierce-pressure mode.
Make sure that the pressure in the hydraulic pump and pressure compensator is increasing.
Make sure that the relief valve on the pump manifold has not failed.
High temperature
The normal operating temperature of the hydraulic fluid is 37.7°C to 43.3°C (100°F to 110°F). High altitude and high
ambient temperatures can have an effect on the temperature of hydraulic fluid. Fluid that is too cool becomes thick and
causes increased friction and poor lubrication. Fluid that is too warm becomes thin, which accelerates wear on the parts,
increases the formation of sludge, degrades the fluid, and decreases lubrication and protective qualities.
A sensor in the hydraulic fluid tank monitors the hydraulic fluid temperature with 3 switches. One switch closes
at 45.0°C (113°F), 1 switch opens at 55.0°C (131°F), and 1 switch opens at 65.0°C (149°F).
The 55.0°C (130°F) alarm permits the primary motor and the intensifier to continue running. The 65.0°C (150°F) alarm
permits the primary motor to continue running for 2 minutes. If the alarm condition is still present, the primary motor turns
off.
An unexpected increase in pump temperature indicates a problem with the cooling system. Check these possible causes.
Symbol
Fault/warning
Stack light
Result
Low hydraulic fluid
Red
The intensifier turns off.
The pump turns off.
Symbol
Fault/warning
Stack light
Result
The hydraulic fluid temperature
is equal to or higher than
55.0°C (131°F)
Amber
The intensifier continues running.
The pump continues running.
The hydraulic fluid temperature
is equal to or higher
than 65.0°C (149°F)
Red
The intensifier turns off.
The pump runs for 2 minutes.
After 2 minutes, the pump turns off.
Summary of Contents for HyPrecision 15
Page 1: ...HyPrecision15 30 50 Waterjet Pump Operator Manual 808240 Revision 1 English ...
Page 10: ...10 HyPrecision15 30 50 Operator Manual 808240 Pump information Pump information ...
Page 12: ...SC 12 Safety and compliance Warranty Warranty ...
Page 16: ...SC 16 Safety and compliance Product stewardship Product stewardship ...
Page 18: ...SC 18 Safety and compliance Environmental stewardship Environmental stewardship ...
Page 24: ...SC 24 Safety and compliance Symbols and marks Symbols and marks ...
Page 28: ...28 HyPrecision15 30 50 Operator Manual 808240 Terminology Terminology ...
Page 44: ...44 HyPrecision15 30 50 Operator Manual 808240 3 Options Options ...
Page 60: ...60 HyPrecision15 30 50 Operator Manual 808240 4 Operation Operation ...
Page 152: ...152 HyPrecision15 30 50 Operator Manual 808240 6 Parts lists Parts lists ...
Page 176: ...176 HyPrecision15 30 50 Operator Manual 808240 8 Pump specifications Pump specifications ...
Page 194: ...194 HyPrecision15 30 50 Operator Manual 808240 9 Installation Installation ...