5 – Preventive maintenance
Preventive maintenance
7.
Torque the output adapter to 41 N ∙ m to 47 N ∙ m (30 lbf ∙ ft to 35 lbf ∙ ft).
8.
Put high-pressure antiseize lubricant on the high-pressure connector threads.
9.
Connect the high-pressure water line.
Make sure that a few of the threads on the collar are visible.
10.
Torque the high-pressure water fitting to 41 N ∙ m to 47 N ∙ m (30 lbf ∙ ft to 35 lbf ∙ ft).