138
HyPrecision15/30/50
Operator
Manual 808240
5 – Preventive maintenance
Preventive maintenance
14.
Check the high-pressure water, the low-pressure water, and the hydraulic systems for leaks. If a leak is found, identify
the source and repair the problem. Refer to the Troubleshooting section, which begins on page 153.
15.
Turn the pierce-pressure adjustment knob to the right (clockwise) to increase the pierce-pressure to the desired
pierce-pressure set point.
16.
Press 1 on the numeric keypad to change the pump to cut-pressure mode. The intensifier strokes until the pump
reaches the high-pressure setting and then it stops stroking.
17.
Check the high-pressure water, the low-pressure water, and the hydraulic systems for leaks. If a leak is found, identify
the source and repair the problem. Refer to the Troubleshooting section, which begins on page 153.
The pump is ready for normal operation.
Summary of Contents for HyPrecision 15
Page 1: ...HyPrecision15 30 50 Waterjet Pump Operator Manual 808240 Revision 1 English ...
Page 10: ...10 HyPrecision15 30 50 Operator Manual 808240 Pump information Pump information ...
Page 12: ...SC 12 Safety and compliance Warranty Warranty ...
Page 16: ...SC 16 Safety and compliance Product stewardship Product stewardship ...
Page 18: ...SC 18 Safety and compliance Environmental stewardship Environmental stewardship ...
Page 24: ...SC 24 Safety and compliance Symbols and marks Symbols and marks ...
Page 28: ...28 HyPrecision15 30 50 Operator Manual 808240 Terminology Terminology ...
Page 44: ...44 HyPrecision15 30 50 Operator Manual 808240 3 Options Options ...
Page 60: ...60 HyPrecision15 30 50 Operator Manual 808240 4 Operation Operation ...
Page 152: ...152 HyPrecision15 30 50 Operator Manual 808240 6 Parts lists Parts lists ...
Page 176: ...176 HyPrecision15 30 50 Operator Manual 808240 8 Pump specifications Pump specifications ...
Page 194: ...194 HyPrecision15 30 50 Operator Manual 808240 9 Installation Installation ...