5 – Preventive maintenance
Preventive maintenance
5.
Put the needle through the needle guide and the valve seal.
Make sure that the point of the needle faces the seal.
6.
Put high-vacuum grease on the red O-ring on the valve seal. Make sure that the red O-ring on the valve seal faces
away from the needle.
7.
Put the needle-and-seal assembly into the valve body until the needle guide is even with the top of the bore.
8.
Install the actuator on the valve body. Turn the actuator until it is hand tight.
1
2
3
4
1
Needle
2
Needle guide
3
Valve seal
4
O-ring
Summary of Contents for HyPrecision 15
Page 1: ...HyPrecision15 30 50 Waterjet Pump Operator Manual 808240 Revision 1 English ...
Page 10: ...10 HyPrecision15 30 50 Operator Manual 808240 Pump information Pump information ...
Page 12: ...SC 12 Safety and compliance Warranty Warranty ...
Page 16: ...SC 16 Safety and compliance Product stewardship Product stewardship ...
Page 18: ...SC 18 Safety and compliance Environmental stewardship Environmental stewardship ...
Page 24: ...SC 24 Safety and compliance Symbols and marks Symbols and marks ...
Page 28: ...28 HyPrecision15 30 50 Operator Manual 808240 Terminology Terminology ...
Page 44: ...44 HyPrecision15 30 50 Operator Manual 808240 3 Options Options ...
Page 60: ...60 HyPrecision15 30 50 Operator Manual 808240 4 Operation Operation ...
Page 152: ...152 HyPrecision15 30 50 Operator Manual 808240 6 Parts lists Parts lists ...
Page 176: ...176 HyPrecision15 30 50 Operator Manual 808240 8 Pump specifications Pump specifications ...
Page 194: ...194 HyPrecision15 30 50 Operator Manual 808240 9 Installation Installation ...