5 – Preventive maintenance
Preventive maintenance
Install the output adapter and the high-pressure poppet assembly
Refer to the Parts lists section, which begins on page 147, for part numbers and ordering information.
Required tools, materials, and parts
15565 HyPrecision basic poppet repair kit
High-pressure antiseize lubricant such as Blue Goop or AccuGoop
1-inch open-ended crowfoot wrench or socket (check valve and output adapter)
13/16-inch open-ended crowfoot wrench or socket (high-pressure water fitting)
Torque wrench
6-inch cotton-tipped applicators (included in the HyPrecision standard tool kit)
1.
Use a cotton-tipped applicator to put high-pressure antiseize lubricant in the recess in the bottom of the check valve.
CAUTION
Overtightening a fitting can cause it to fail. Use 2 wrenches when loosening or tightening a high-pressure
connection. Using only 1 wrench can increase bending stress to the parts and cause damage or premature
failure.
Put the parts on a clean, dry, oil-free surface.
1
2
3
4
1
High-pressure poppet seat
2
High-pressure poppet
3
High-pressure poppet spring
4
Output adapter
Summary of Contents for HyPrecision 15
Page 1: ...HyPrecision15 30 50 Waterjet Pump Operator Manual 808240 Revision 1 English ...
Page 10: ...10 HyPrecision15 30 50 Operator Manual 808240 Pump information Pump information ...
Page 12: ...SC 12 Safety and compliance Warranty Warranty ...
Page 16: ...SC 16 Safety and compliance Product stewardship Product stewardship ...
Page 18: ...SC 18 Safety and compliance Environmental stewardship Environmental stewardship ...
Page 24: ...SC 24 Safety and compliance Symbols and marks Symbols and marks ...
Page 28: ...28 HyPrecision15 30 50 Operator Manual 808240 Terminology Terminology ...
Page 44: ...44 HyPrecision15 30 50 Operator Manual 808240 3 Options Options ...
Page 60: ...60 HyPrecision15 30 50 Operator Manual 808240 4 Operation Operation ...
Page 152: ...152 HyPrecision15 30 50 Operator Manual 808240 6 Parts lists Parts lists ...
Page 176: ...176 HyPrecision15 30 50 Operator Manual 808240 8 Pump specifications Pump specifications ...
Page 194: ...194 HyPrecision15 30 50 Operator Manual 808240 9 Installation Installation ...