HyPrecision15/30/50
Operator
Manual 808240
135
5 – Preventive maintenance
Preventive maintenance
Install the bleed-down valve
Required tools, materials, and parts
5/8-inch open-ended wrench
3/4-inch open-ended wrench
13/16-inch open-ended wrench
1-inch open-ended wrench
Torque wrench
1.
Tighten the gland nut on the high-pressure collar at the high-pressure fitting of the valve. Refer to the Fittings section,
which begins on page 173, for the fittings torque values.
2.
Tighten the gland nut connecting the water drain tubing to the bleed-down valve. Refer to the Fittings section, which
begins on page 173, for the fittings torque values.
CAUTION
Overtightening a fitting can cause it to fail. Use 2 wrenches when loosening or tightening a high-pressure
connection. Using only 1 wrench can increase bending stress to the parts and cause damage or premature
failure.
Summary of Contents for HyPrecision 15
Page 1: ...HyPrecision15 30 50 Waterjet Pump Operator Manual 808240 Revision 1 English ...
Page 10: ...10 HyPrecision15 30 50 Operator Manual 808240 Pump information Pump information ...
Page 12: ...SC 12 Safety and compliance Warranty Warranty ...
Page 16: ...SC 16 Safety and compliance Product stewardship Product stewardship ...
Page 18: ...SC 18 Safety and compliance Environmental stewardship Environmental stewardship ...
Page 24: ...SC 24 Safety and compliance Symbols and marks Symbols and marks ...
Page 28: ...28 HyPrecision15 30 50 Operator Manual 808240 Terminology Terminology ...
Page 44: ...44 HyPrecision15 30 50 Operator Manual 808240 3 Options Options ...
Page 60: ...60 HyPrecision15 30 50 Operator Manual 808240 4 Operation Operation ...
Page 152: ...152 HyPrecision15 30 50 Operator Manual 808240 6 Parts lists Parts lists ...
Page 176: ...176 HyPrecision15 30 50 Operator Manual 808240 8 Pump specifications Pump specifications ...
Page 194: ...194 HyPrecision15 30 50 Operator Manual 808240 9 Installation Installation ...