5 – Preventive maintenance
Preventive maintenance
Install the seal housing assembly and plunger bearing
Refer to the Parts lists section, which begins on page 147, for part numbers and ordering information.
Required tools, materials, and parts
15563 HyPrecision premium high-pressure seal kit
ISO viscosity grade (VG) 32 or 46 antiwear mineral or synthetic hydraulic fluid
Seal installation tools (included in the HyPrecision standard tool kit)
1.
Examine the seal housing and the high-pressure seal backup. Make sure that the weep holes and inside grooves are
clear of debris.
2.
Put O-ring lubricant on the backup ring and the O-ring.
Put the parts on a clean, dry, oil-free surface.
1
2
3
4
1
2
3
4
1
High-pressure seal backup
2
Seal housing
3
Hydraulic rod seal
4
Plunger bearing
1
2
1
Weep holes
2
Grooves
Summary of Contents for HyPrecision 15
Page 1: ...HyPrecision15 30 50 Waterjet Pump Operator Manual 808240 Revision 1 English ...
Page 10: ...10 HyPrecision15 30 50 Operator Manual 808240 Pump information Pump information ...
Page 12: ...SC 12 Safety and compliance Warranty Warranty ...
Page 16: ...SC 16 Safety and compliance Product stewardship Product stewardship ...
Page 18: ...SC 18 Safety and compliance Environmental stewardship Environmental stewardship ...
Page 24: ...SC 24 Safety and compliance Symbols and marks Symbols and marks ...
Page 28: ...28 HyPrecision15 30 50 Operator Manual 808240 Terminology Terminology ...
Page 44: ...44 HyPrecision15 30 50 Operator Manual 808240 3 Options Options ...
Page 60: ...60 HyPrecision15 30 50 Operator Manual 808240 4 Operation Operation ...
Page 152: ...152 HyPrecision15 30 50 Operator Manual 808240 6 Parts lists Parts lists ...
Page 176: ...176 HyPrecision15 30 50 Operator Manual 808240 8 Pump specifications Pump specifications ...
Page 194: ...194 HyPrecision15 30 50 Operator Manual 808240 9 Installation Installation ...