5 – Preventive maintenance
Preventive maintenance
Remove the high-pressure end cap
Required tools, materials, and parts
Clean, lint-free towel
Isopropyl alcohol
13/16-inch open-ended wrench (high-pressure water fitting)
7/8-inch open-ended wrench (low-pressure water fitting)
Square drive socket, 1-1/2 inch × 3/4 inch (stud nuts) (included in the HyPrecision standard tool kit)
1.
Disconnect the low-pressure water line.
2.
Disconnect the high-pressure water line.
3.
Remove the stud nuts.
4.
Pull the end cap off.
5.
Clean each part with a lint-free towel and isopropyl alcohol.
6.
Examine all parts for deterioration, corrosion, or damage.
7.
Clean and examine parts that will be replaced to identify wear patterns or damage that can signify other problems.
Do not use soap, detergent, or solvents.
1
2
3
4
1
Studs
2
Low-pressure water fitting
3
High-pressure end cap
4
Stud nuts
Summary of Contents for HyPrecision 15
Page 1: ...HyPrecision15 30 50 Waterjet Pump Operator Manual 808240 Revision 1 English ...
Page 10: ...10 HyPrecision15 30 50 Operator Manual 808240 Pump information Pump information ...
Page 12: ...SC 12 Safety and compliance Warranty Warranty ...
Page 16: ...SC 16 Safety and compliance Product stewardship Product stewardship ...
Page 18: ...SC 18 Safety and compliance Environmental stewardship Environmental stewardship ...
Page 24: ...SC 24 Safety and compliance Symbols and marks Symbols and marks ...
Page 28: ...28 HyPrecision15 30 50 Operator Manual 808240 Terminology Terminology ...
Page 44: ...44 HyPrecision15 30 50 Operator Manual 808240 3 Options Options ...
Page 60: ...60 HyPrecision15 30 50 Operator Manual 808240 4 Operation Operation ...
Page 152: ...152 HyPrecision15 30 50 Operator Manual 808240 6 Parts lists Parts lists ...
Page 176: ...176 HyPrecision15 30 50 Operator Manual 808240 8 Pump specifications Pump specifications ...
Page 194: ...194 HyPrecision15 30 50 Operator Manual 808240 9 Installation Installation ...