102
HyPrecision15/30/50
Operator
Manual 808240
5 – Preventive maintenance
Preventive maintenance
Service the intensifier
Consider doing preventive maintenance on both high-pressure ends to reduce unplanned downtime.
Refer to the Parts lists section, which begins on page 147, for part numbers and ordering information.
Required tools, materials, and parts
13/16-inch open-ended wrench (high-pressure water fitting)
7/8-inch open-ended wrench (low-pressure water fitting)
1-inch open-ended wrench (output adapter)
1-1/6-inch open-ended wrench (high-pressure water fitting)
CAUTION
Failure to correct the cause of a leak can result in damage to the fittings.
CAUTION
Overtightening a fitting can cause it to fail. Use 2 wrenches when loosening or tightening a high-pressure
connection. Using only 1 wrench can increase bending stress to the parts and cause damage or premature
failure.
Repair or replace parts identified in the preventive maintenance schedule or if the parts show signs of
deterioration, corrosion, or damage.
Put the parts on a clean, dry, oil-free surface.
Do not use an adjustable wrench on high-pressure fittings.
1
2
3
4
1
High-pressure ends
2
Attenuator
3
High-pressure water fitting
4
Bleed-down valve
Summary of Contents for HyPrecision 15
Page 1: ...HyPrecision15 30 50 Waterjet Pump Operator Manual 808240 Revision 1 English ...
Page 10: ...10 HyPrecision15 30 50 Operator Manual 808240 Pump information Pump information ...
Page 12: ...SC 12 Safety and compliance Warranty Warranty ...
Page 16: ...SC 16 Safety and compliance Product stewardship Product stewardship ...
Page 18: ...SC 18 Safety and compliance Environmental stewardship Environmental stewardship ...
Page 24: ...SC 24 Safety and compliance Symbols and marks Symbols and marks ...
Page 28: ...28 HyPrecision15 30 50 Operator Manual 808240 Terminology Terminology ...
Page 44: ...44 HyPrecision15 30 50 Operator Manual 808240 3 Options Options ...
Page 60: ...60 HyPrecision15 30 50 Operator Manual 808240 4 Operation Operation ...
Page 152: ...152 HyPrecision15 30 50 Operator Manual 808240 6 Parts lists Parts lists ...
Page 176: ...176 HyPrecision15 30 50 Operator Manual 808240 8 Pump specifications Pump specifications ...
Page 194: ...194 HyPrecision15 30 50 Operator Manual 808240 9 Installation Installation ...