VRVIII system indoor unit

OPERATION MANUAL

HXHD125A7V1B

 system indoor unit

Summary of Contents for VRVIII

Page 1: ...VRVIII system indoor unit OPERATION MANUAL HXHD125A7V1B system indoor unit...

Page 2: ...ppliance by a person responsible for their safety Children shall be supervised to ensure that they do not play with the appliance 1 DEFINITIONS 1 1 Meaning of warnings and symbols Warnings in this man...

Page 3: ...Scope of this manual This manual describes how to start up and switch off the unit set parameters and con gure the schedule timer by means of the controller maintain the unit and solve operational pr...

Page 4: ...up and the unit will start For further details and advised settings see 5 3 Space heating operation h h h h on page 6 Domestic water heating only if domestic hot water tank option is installed Automat...

Page 5: ...PLAY 9 The display shows the current temperature of the installation either leaving water set point temperature or actual room temperature When changing the room temperature set point the set point wi...

Page 6: ...it outdoor ambient temperature actual room temperature and domestic hot water temperature and in schedule timer programming mode 29 LEAVING WATER TEMPERATURE ADJUST BUTTONS bi and bj These buttons are...

Page 7: ...mperature The setback function can for instance be activated during the night because the temperature demands during night and day are not the same The setback function is con gured through eld settin...

Page 8: ...s the ba button 1 time to select weather dependent set point operation or 2 times when the remote controller room thermostat function is used Icon a appears on the display as well as the shift value T...

Page 9: ...when space heating requirements are lower until the storage temperature set point is reached The heated water is stored in the domestic hot water tank at a higher temperature so it can ful l the dome...

Page 10: ...too so that storage temperature set point can be set lower in order to keep the overall equivalent hot water amount the same during the whole year Therefor it is recommended to use this function b 04...

Page 11: ...to ON 5 5 Other operation modes Start up operation d During start up the d icon displays indicating that the heat pump is starting up and is not working in a steady state condition Defrost operation d...

Page 12: ...allation is controlled by the schedule timer The actions programmed in the schedule timer will be executed automatically The schedule timer is enabled p icon displayed or disabled p icon not displayed...

Page 13: ...will remain active until the next programmed command 19 00 occurs So in order to know the actual setting one should consult the last programmed command It is clear that the last programmed command ma...

Page 14: ...out the form at the very end of this manual This form can help you de ne the required actions for each day Take your time to enter all data accurately Try to program the actions in a chronological wa...

Page 15: ...i and bj buttons to set the room temperature 11 Use the ba button to select x to switch heating and the remote controller off a to select automatic temperature calculation for leaving water temperatur...

Page 16: ...tton to select the action number you would like to program or to modify 8 Use the pi and pj buttons to set the correct action time 9 Use the ba button to select or deselect x as action 10 Repeat steps...

Page 17: ...fy 7 Use the pi and pj buttons to set the correct action time 8 Use the ba button to select or deselect x as action 9 Repeat steps 6 to 8 to program the other actions of the selected mode When all act...

Page 18: ...return to step 2 by pressing the pr button Deleting one or more programmed actions Deleting one or more programmed actions is done at the same time as storing the programmed actions When all actions...

Page 19: ...t selected eld setting code is indicated 2 with the set value displayed to the right 1 2 Press the bi button to select the appropriate eld setting rst code 3 Press the bj button to select the appropri...

Page 20: ...mperature Lo_Ti 70 25 80 1 C 03 Set point at high ambient temperature Hi_Ti 45 25 80 1 C 4 Disinfection function 00 Status disinfection operation 1 ON 0 1 01 Disinfection operation day selection Fri M...

Page 21: ...icable Do not change the default value 20 03 Not applicable Do not change the default value 5 04 Not applicable Do not change the default value 0 d Domestic water heating retention times 00 Installati...

Page 22: ...for diagnosing and correcting certain problems which may occur with the unit WARNING If the supply cord is damaged it must be replaced by the manufacturer its agent or similar quali ed persons in orde...

Page 23: ......

Page 24: ...4PW62585 1 11 2010 Copyright 2011 Daikin...