Model: FWAP to be used with any CS model heater
Any of the following models may be replaced using the FW conversion kit:
FW051, RW051, FW052, RW052, FW071, RW071, FW751, RW071, FW752, RW752
FW072, RW072, FW101, RW101, FW102, RW102, FW121, RW121, FW122, RW122
FW151, RW151, FW152, RW152, FW202, RW202, FW252, RW252, FW302, RW302
*The above models may be controlled by either a built-in thermostat or a wall mount thermostat.
General Safety Information
PARTS INClUDED:
3 Screws
2 Spring Nuts
2 Lead Wires
1 Replacement Grill Label
2 Mounting Screws
1 Conversion Plate
3 Lock Tooth Washers
1 Instruction Guide
TOOlS REqUIRED:
Phillips Screwdriver
Straight Screwdriver
WARNING!
Turn the electrical power off at the
electrical panel board (circuit
breaker or fuse box) and lock or
tag the panel board door to
prevent someone from turning on
power while you are working on
the heater. Failure to do so could
result in serious electrical shock,
burns, or possible death.
1.
WARNING
Risk of fire or property damage.
DO NOT
replace your heater with a higher wattage assembly.
Replace your heater with the same voltage and wattage that
was originally installed. Replacing it with a higher wattage
heater could result in an overloaded electrical circuit in your
home, which could result in a fire and serious property damage.
Replacing with a lower wattage heater may cause insufficient
heat and result in increased energy costs.
2.
All electrical work and materials must comply with the National
Electric Code (NEC), the Occupational Safety and Health Act
(OSHA), and all state and local codes.
3.
When installing the heater conversion kit, be certain the FW
heater being replaced was wired correctly to all electrical codes
and the supply wiring is the correct size and in good condition.
If not, it must be replaced before proceeding.
4.
If you need to install a new circuit or need additional wiring
information, consult a qualified electrician.
5.
Protect electrical supply from kinks, sharp objects, oil, grease,
hot surfaces or chemicals.
Features & Benefits
•
Converts discontinued FW Series wall can
to newer Com-Pak or Com-Pak Max
•
UL Listed for installation of Com-Pak
model into FW wall can
•
No sheetrock construction necessary -
saves time and money
•
Vertical or horizontal installation
If you are uncomfortable working with electrical appliances, unable to follow these guidelines,
or do not have the necessary equipment, consult a licensed electrician.
vertical installation shown
1
SAVE THESE INSTRUCTIONS
cadetheat.com Tel: 360-693-2505 P.O. Box 1675 Vancouver, WA 98668-1675
©2014 Cadet Printed in U.S.A. 12/14 #720027
FWAP Conversion Kit
Installation Instructions