Password Setups
316
Baud Rate
Allows selection of the desired baud rate for the remote Communications Link. The available Baud
rates are shown. The control also incorporates a unique compression utility that allows the effective
baud rate to be doubled. For example, for links configured to run at 9600 baud, the effective rate will
be 19.2K Baud.
Note: For Serial Messaging communication speeds from 1200 Baud to 115200 Baud are available.
See Serial Messaging in the Program Code section for more information.
Parity
Enter the desired parity for the remote Communications Link.
Data Bits
Enter the number of data bits the remote link is using. This value is
8
for the link software included
with the control.
Time Out Delay
Enter the amount of time the control will wait prior to display communications error should it not be
able to establish a link with a remote device.
Transmit Delay
Enter the amount of delay the control will insert between each character that is transmitted over the
serial port. Some communications links require a small delay to avoid missing characters that have
been sent to them. This parameter should normally be set to zero.
The following parameters allow the user to create a custom communication link on the control by
entering the ASCII code equivalent to the character or symbol used by the host computer for dialog
start.
For example: The ASCII Decimal Code 33 is equal to the
!
symbol
Rewind
This setup parameter is only enabled when Link File Dump Mode has been enable. Enter the ASCII
code equivalent to the character or symbol used by the host computer for tape rewind at the host tape
drive system. Enter the number zero to eliminate the rewind command.
Dialog Start
Enter the ASCII code equivalent to the character or symbol used by the host computer for dialog
start.
Dialog Done
Enter the ASCII code equivalent to the character or symbol used by the host computer for dialog
done.
Dialog Prompt
Enter the ASCII code equivalent to the character or symbol used by the host computer for dialog
rompt.
Summary of Contents for Edge TI
Page 24: ...Table of Contents XXII...
Page 41: ...Overview 17 Alpha Numeric Keypad Numeric Keypad...
Page 54: ...Overview 30...
Page 83: ...Setups 59 Water Jet Press the Timing Diagram soft key to view the timing diagram from setups...
Page 88: ...Setups 64...
Page 116: ...Shape Manager 92...
Page 128: ...Files 104...
Page 280: ...Part Options 256...
Page 317: ...Diagnostics 293 DriveTop from Indramat...
Page 402: ...Phoenix Link 378...
Page 420: ...Sensor THC 396...
Page 428: ...Command THC 404...
Page 436: ...Motion Overview 412 Motion Tuning Watch Windows Position and Following Error may be displayed...
Page 470: ...Program Codes 446...
Page 478: ...Automated Plasma Interface 454 Inputs...
Page 479: ...Automated Plasma Interface 455 Inputs...
Page 480: ...Automated Plasma Interface 456 Outputs...
Page 496: ...Automated Plasma Interface 472...
Page 520: ...MicroEdge 496...
Page 532: ...Edge Ti 508 Optional Motor Information...
Page 540: ...Edge Ti 516...
Page 546: ...Voyager III 522 Examples of possible circuits Output Input 24 VDC Com...
Page 557: ...Networking 533 7 Double Click on the network interface connected to your LAN...
Page 558: ...Networking 534...
Page 561: ...Networking 537...
Page 562: ...Networking 538 13 Double click on the System 14 Select the Computer Name tab...
Page 572: ...Networking 548...
Page 573: ......