Automated Plasma Interface
470
FineLine Part Program Support
The same Cut Chart data which is used at the Cut Chart setup screen may also be used within a part
program to configure the FineLine for use. This code is used to select the set point for each variable.
It is not necessary to have a line of code for each Cut Chart variable within a part program. Only
those variables which are changing need be inserted into the part program (e.g. Material Thickness or
Material Type).
Part program codes for the FineLine should be grouped together at the beginning of the program.
The three variables which may be set through the part program are Material Type, Current Setting
and Material Thickness.
Cut parameters for the FineLine may be configured using a EIA-274D G59 code with the following
format.
Example:
G59 V503 F5
Misc. G Code
Variable Identity
V503
– Material Type Plasma 1
V513
– Material Type Plasma 2
V523
– Material Type Marker 1
V533
– Material Type Marker 2
V504
– Current Setting Plasma 1
V514
– Current Setting Plasma 2
V524
– Current Setting Marker 1
V534
– Current Setting Marker 2
V507
– Material Thickness Plasma 1
V517
– Material Thickness Plasma 2
V527
– Material Thickness Marker 1
V537
– Material Thickness Marker 2
Variable Value
V503, V513, V523, V533
– Material Type
1 = Mild Steel
2 = Stainless Steel
3 = Aluminum
V504, V514, V524, 534
– Current Setting
8 = 8A
50 = 50A
9 = 9A
70 = 70A
10 = 10A
100 = 100A
30 = 30A
200 = 200A
Summary of Contents for Edge TI
Page 24: ...Table of Contents XXII...
Page 41: ...Overview 17 Alpha Numeric Keypad Numeric Keypad...
Page 54: ...Overview 30...
Page 83: ...Setups 59 Water Jet Press the Timing Diagram soft key to view the timing diagram from setups...
Page 88: ...Setups 64...
Page 116: ...Shape Manager 92...
Page 128: ...Files 104...
Page 280: ...Part Options 256...
Page 317: ...Diagnostics 293 DriveTop from Indramat...
Page 402: ...Phoenix Link 378...
Page 420: ...Sensor THC 396...
Page 428: ...Command THC 404...
Page 436: ...Motion Overview 412 Motion Tuning Watch Windows Position and Following Error may be displayed...
Page 470: ...Program Codes 446...
Page 478: ...Automated Plasma Interface 454 Inputs...
Page 479: ...Automated Plasma Interface 455 Inputs...
Page 480: ...Automated Plasma Interface 456 Outputs...
Page 496: ...Automated Plasma Interface 472...
Page 520: ...MicroEdge 496...
Page 532: ...Edge Ti 508 Optional Motor Information...
Page 540: ...Edge Ti 516...
Page 546: ...Voyager III 522 Examples of possible circuits Output Input 24 VDC Com...
Page 557: ...Networking 533 7 Double Click on the network interface connected to your LAN...
Page 558: ...Networking 534...
Page 561: ...Networking 537...
Page 562: ...Networking 538 13 Double click on the System 14 Select the Computer Name tab...
Page 572: ...Networking 548...
Page 573: ......