Program Codes
432
Sensor THC Part Program Support
Sensor™ THC offers the ability to configure THC setup parameters through part program codes.
The following parameters are available for use using EIA-274D G59 codes:
Arc Voltage
Pierce / Start Time
Pierce/ Start Height Factor
Cut / Mark Height
Setup is obtained using the following format.
Example:
G59 V601 F
value
Misc. G Code
Variable Identity
V600 = Plasma 1 Arc Voltage
V601 = Plasma 1 Pierce Time
V602 = Plasma 1 Pierce Height Factor
V603 = Plasma 1 Cut Height
V625 = Plasma 2 Arc Voltage
V626 = Plasma 2 Pierce Time
V627 = Plasma 2 Pierce Height Factor
V628 = Plasma 2 Cut Height
V650 = Marker 1 Arc Voltage
V651 = Marker 1 Start Time
V652 = Marker 1 Start Height Factor
V653 = Marker 1 Mark Height
V675 = Marker 2 Arc Voltage
V676 = Marker 2 Start Time
V677 = Marker 2 Start Height Factor
V678 = Marker 2 Mark Height
Variable Value
The selected value for the variable
THC Index code
G00 Zx.xx Tx
Index Sensor™ THC height “Z” distance for torch “T”. Manual mode only.
Summary of Contents for Edge TI
Page 24: ...Table of Contents XXII...
Page 41: ...Overview 17 Alpha Numeric Keypad Numeric Keypad...
Page 54: ...Overview 30...
Page 83: ...Setups 59 Water Jet Press the Timing Diagram soft key to view the timing diagram from setups...
Page 88: ...Setups 64...
Page 116: ...Shape Manager 92...
Page 128: ...Files 104...
Page 280: ...Part Options 256...
Page 317: ...Diagnostics 293 DriveTop from Indramat...
Page 402: ...Phoenix Link 378...
Page 420: ...Sensor THC 396...
Page 428: ...Command THC 404...
Page 436: ...Motion Overview 412 Motion Tuning Watch Windows Position and Following Error may be displayed...
Page 470: ...Program Codes 446...
Page 478: ...Automated Plasma Interface 454 Inputs...
Page 479: ...Automated Plasma Interface 455 Inputs...
Page 480: ...Automated Plasma Interface 456 Outputs...
Page 496: ...Automated Plasma Interface 472...
Page 520: ...MicroEdge 496...
Page 532: ...Edge Ti 508 Optional Motor Information...
Page 540: ...Edge Ti 516...
Page 546: ...Voyager III 522 Examples of possible circuits Output Input 24 VDC Com...
Page 557: ...Networking 533 7 Double Click on the network interface connected to your LAN...
Page 558: ...Networking 534...
Page 561: ...Networking 537...
Page 562: ...Networking 538 13 Double click on the System 14 Select the Computer Name tab...
Page 572: ...Networking 548...
Page 573: ......