Automated Plasma Interface
449
Kerf
Specifies the amount of kerf (cutter compensation) that will be applied to the current part program.
Set Arc Voltage
The operator may input the desired Arc Voltage for the material being cut.
Cut Height
The Cut Height setup parameter is used to select the desired cut distance from the plate.
Pierce Height
The Pierce Height setup parameter is used to select the desired Pierce Height. This may be entered
as a multiplication factor that is calculated times the Cut Height or an actual Pierce Height distance.
Preflow Setting
The appropriate Plasma / Shield Preflow percentages for the desired process may be selected.
Cutflow Settings
The appropriate Plasma / Shield Cutflow percentages for the desired process may be selected.
Preflow Time
Specifies the amount of time the Preflow gases are on.
Purge Time
Specifies the time delay from torch ignition until motion is enabled.
Pierce Time
Specifies the time delay from when torch completes lowering until motion is initiated at Creep Speed.
Used to allow the plasma torch to completely pierce the material before moving.
Creep Time
Specifies the amount of time after piercing the part that the torch travels at Creep Speed. Creep
Speed is determined by a setup parameter at the Speeds setup screen and is a percentage of the
programmed cut speed. After the Creep Time is completed, the control accelerates to full cut speed.
Save Process
Pressing the Save Process soft key allows the user to save the current process settings to the Hard
drive creating a custom user database based on the eight process variables selected.
Reset Process
Pressing the Reset Process soft key allows the user to reset the current settings to factory
recommend factory defaults based on the eight process variables selected.
Summary of Contents for Edge TI
Page 24: ...Table of Contents XXII...
Page 41: ...Overview 17 Alpha Numeric Keypad Numeric Keypad...
Page 54: ...Overview 30...
Page 83: ...Setups 59 Water Jet Press the Timing Diagram soft key to view the timing diagram from setups...
Page 88: ...Setups 64...
Page 116: ...Shape Manager 92...
Page 128: ...Files 104...
Page 280: ...Part Options 256...
Page 317: ...Diagnostics 293 DriveTop from Indramat...
Page 402: ...Phoenix Link 378...
Page 420: ...Sensor THC 396...
Page 428: ...Command THC 404...
Page 436: ...Motion Overview 412 Motion Tuning Watch Windows Position and Following Error may be displayed...
Page 470: ...Program Codes 446...
Page 478: ...Automated Plasma Interface 454 Inputs...
Page 479: ...Automated Plasma Interface 455 Inputs...
Page 480: ...Automated Plasma Interface 456 Outputs...
Page 496: ...Automated Plasma Interface 472...
Page 520: ...MicroEdge 496...
Page 532: ...Edge Ti 508 Optional Motor Information...
Page 540: ...Edge Ti 516...
Page 546: ...Voyager III 522 Examples of possible circuits Output Input 24 VDC Com...
Page 557: ...Networking 533 7 Double Click on the network interface connected to your LAN...
Page 558: ...Networking 534...
Page 561: ...Networking 537...
Page 562: ...Networking 538 13 Double click on the System 14 Select the Computer Name tab...
Page 572: ...Networking 548...
Page 573: ......