Password Setups
323
Station Select Input
The type “V” control system has the ability to operate multiple Sensor™
THCs which are commanded by the control as separate axes. The
control requires an input to indicate which Sensor™ THCs are active.
This Input is also used for tracking of consumable data for the specified
Plasma or Oxy Torch. Stations 1-8 are designated for Plasma and
stations 9-20 are designated for Oxy Fuel.
X Home Switch
This input indicates that the machine has traveled to its X axis home
position. If the X axis “Use Home Limit Switch” parameter is set to YES
and a Homing function is performed, the X axis moves in the specified
home direction at the Fast Home Speed until the input is activated. The
X axis then decelerates to a stop and moves in the opposite direction at
the Slow Home Speed until the switch is deactivated. Once the switch is
deactivated, the X axis will either decel to a stop or continue on until the
encoder marker pulse is detected, if the “Use Marker Pulse” parameter is
set to YES.
Y Home Switch
This input indicates that the machine has traveled to its Y axis home
position. If the Y axis “Use Home Limit Switch” parameter is set to YES
and a Homing function is performed, the Y axis moves in the specified
home direction at the Fast Home Speed until the input is activated. The
Y axis then decelerates to a stop and moves in the opposite direction at
the Slow Home Speed until the switch is deactivated. Once the switch is
deactivated, the Y axis will either decel to a stop or continue on until the
encoder marker pulse is detected, if the “Use Marker Pulse” parameter is
set to YES.
Z Home Switch
Z Axis Home Limit Switch indicates that the machine has traveled to its Z
axis home position. If the Z axis “Use Home Limit Switch” parameter is
set to YES and a Homing function is performed, the Z axis moves in the
specified home direction at the Fast Home Speed until the input is
activated. The Z axis then decelerates to a stop and moves in the
opposite direction at the Slow Home Speed until the switch is
deactivated. Once the switch is deactivated, the Z axis will either decel to
a stop or continue on until the encoder marker pulse is detected, if the
“Use Marker Pulse” parameter is set to YES.
Y Overtravel Switch
This input indicates that the machine has traveled into its full positive
travel of a Y axis. If the hardware overtravels are enabled and this input
is activated, the control will stop all motion and generate a fault
message. Motion will not be re-enabled until the switch is deactivated.
X Overtravel Switch
This input indicates that the machine has traveled into its full positive
travel of a X axis. If the hardware overtravels are enabled and this input
is activated, the control will stop all motion and generate a fault
message. Motion will not be re-enabled until the switch is deactivated.
Limit Switch
This input indicates that the machine has traveled into its full positive
travel of an axis. If the hardware overtravels are enabled and this input is
activated, the control will stop all motion and generate a fault message.
Motion will not be re-
enabled until the switch is deactivated. (Type “M”
configuration only)
Ready to Fire PS 1-4
Exclusive to the HD4070
®
multiple power supply configuration, the
Ready to Fire Input is used to ensure that all HD4070
®
power supplies
have completed each individual Initial Height Sense and are ready for
Summary of Contents for Edge TI
Page 24: ...Table of Contents XXII...
Page 41: ...Overview 17 Alpha Numeric Keypad Numeric Keypad...
Page 54: ...Overview 30...
Page 83: ...Setups 59 Water Jet Press the Timing Diagram soft key to view the timing diagram from setups...
Page 88: ...Setups 64...
Page 116: ...Shape Manager 92...
Page 128: ...Files 104...
Page 280: ...Part Options 256...
Page 317: ...Diagnostics 293 DriveTop from Indramat...
Page 402: ...Phoenix Link 378...
Page 420: ...Sensor THC 396...
Page 428: ...Command THC 404...
Page 436: ...Motion Overview 412 Motion Tuning Watch Windows Position and Following Error may be displayed...
Page 470: ...Program Codes 446...
Page 478: ...Automated Plasma Interface 454 Inputs...
Page 479: ...Automated Plasma Interface 455 Inputs...
Page 480: ...Automated Plasma Interface 456 Outputs...
Page 496: ...Automated Plasma Interface 472...
Page 520: ...MicroEdge 496...
Page 532: ...Edge Ti 508 Optional Motor Information...
Page 540: ...Edge Ti 516...
Page 546: ...Voyager III 522 Examples of possible circuits Output Input 24 VDC Com...
Page 557: ...Networking 533 7 Double Click on the network interface connected to your LAN...
Page 558: ...Networking 534...
Page 561: ...Networking 537...
Page 562: ...Networking 538 13 Double click on the System 14 Select the Computer Name tab...
Page 572: ...Networking 548...
Page 573: ......