1 2 3 4
SETUP
CommandTHC for X-Y Table
Instruction Manual
3-17
11
*DIP Switch Settings
1
2
3
4
Plasma
Fast/Slow
Conv/HyDef
Limited Down
HPR
Systems
Response
Resolution
Speed
pierce
complete
HD3070
OFF
OFF
OFF
OFF
HT2000
OFF
ON
ON
OFF
HT2000LHF
OFF
ON
ON
OFF
MAX100
ON
ON
ON
OFF
MAX200
OFF
ON
ON
OFF
HT4001
ON
ON
ON
OFF
HT4400
ON
ON
ON
OFF
HD4070
ON
OFF
OFF
OFF
Powermax
ON
ON
ON
OFF
HPR/HSD
ON
ON
ON
ON
DIP switch positions
1
Fast/Slow response
• ON slows response speed of lifter by approximately one half in both up and down directions.
• OFF enables "normal" or fast response.
2
Conventional/HyDefinition resolution
• ON enables the THC to respond to larger voltage error changes.
• OFF enables the THC to respond to smaller error voltage changes.
3
Limited down speed
• ON enables lifter to move up at the normal speed, but down at slower speed. This is designed to help where
corner diving is a problem.
• OFF enables the lifter to move up and down at the "normal" speed.
4
HPR pierce complete
* These are recommended switch settings. Since cutting machine installations vary, these switches can be
adjusted in any combination to achieve desired results.
As shipped
DIP switch ON/OFF positions
OFF