Power
Plasma
Supply
CNC
Interface
Signal Name
Color
End (1X1)
End
End
Function
Hold I/O –
Black
1
Not
J4-6
(Optional)
Hold Ignition (I/O) signal used for preflow
Hold I/O +
Red
5
Connected
J4-5
during IHS. Also used by power unit to synchronize
Drain
Drain
10
operation of multiple torch installations.
Pierce Co
Black
2
Not
J4-8
(Optional)
Pierce Complete signal used by power
Pierce Complete –
White
6
Connected
J4-7
unit to time transition from pierce gas flow to cut gas
Drain
Drain
11
flow. User enters this time delay into THC.
Pilot Arc Out +
Black
3
Not
J3-4
(Optional)
Pilot Arc Out signal. Maintained during
Pilot Arc Out –
Green
7
Connected
J3-3
torch ignition. Contact closes after torch ignition. Dry
Drain
Drain
12
contact closure.
Plasma Start –
Black
9
Not
J4-4
Plasma On signal maintained during plasma cut. If
Plasma Start +
Yellow
15
Connected
J4-3
signal is lost, system must be restarted.
Drain
Drain
14
Transfer Out +
Black
37
Not
J3-2
Arc Transfer signal. Contact closes after arc transfer
Transfer Out –
Orange
32
Connected
J3-1
and pierce delay (set on power supply front panel).
Drain
Drain
26
Dry contact closure.
Power Off
Black
4
4
Not
Power Off
Blue
8
8
Connected
Drain
Drain
13
13
External Interlock
Red
16
16
Not
External Interlock
Blue
17
17
Connected
Drain
Drain
18
18
Power On Input
Black
29
29
Not
These signals connect to the CNC. Refer to HD3070
Power On Input
Brown
34
34
Connected
Instruction manual for signal information.
Drain
Drain
23
23
Power Interlocks
Red
35
35
Not
Power Interlocks
White
30
30
Connected
Drain
Drain
24
24
1/50 AC Volts
Red
33
33
Not
1/50 AC Volt
Green
28
28
Connected
Drain
Drain
37
37
HD3070 SETUP
3a-6
CommandTHC for X-Y Table
Instruction Manual
9
Figure 3a-3 HD3070 interface cable – part number and signal list
Part number
Description
Length
123270
HD3070 Power Supply Interface Cable
6 ft./1.8 m
1X1
1X1
Shaded area indicates plasma interface assembly connections.
Plasma interface assembly other J3 and J4 connection points:
• J3-5 (+) and J3-6 (–) – Alternate Nozzle Contact. An optically isolated signal that indicates nozzle is in ohmic contact with work.
Ohmic contact is represented by a logic 1.
• J3-7 through J3-12 – Reserved for future use.
• J3-13 and J3-14 – Protective earth ground.
• J4-1 (+) and J4-2 (–) – Available 24 VDC, 500 mA maximum