HPR SETUP
CommandTHC for X-Y Table
Instruction Manual
3i-5
Plasma interface and I/O board connections
See Figures 3i-4, .3i-5, 3i-6, and 3i-7
Cut the cable tie on the wires bundled below the plasma interface board (numbered 25 and 26).
Attach wire number 25 to stud marked WORK, and wire number 26 to stud marked ELECTRODE.
Cut the cable tie on the wires bundled near the I/O board (numbered 25 and 26).
Connect wire Number 25 to the bus bar marked WORK (+).
Connect wire Number 26 to the bus bar marked TORCH (–).
Secure all wires and cables as required.
C
B
A
D
Bundled wires
held in place with
a cable tie
A
B
Figure 3i-4 Plasma interface wire location
Figure 3i-5 Plasma interface PC board connection
25
26
11