CommandTHC for X-Y Table
Instruction Manual
Page of
Change
Description of Change
Rev 10 to 11
2/2009
Global
Updated formats to current style for TOCs and converted font from Helvetica to Akzidenz.
i and ii
Updated the EMC and Warranty sections to new format
1c
Added section 1c (Spanish safety section) and updated 1a and 1b.
Global
Updated graphics of the plasma interface assembly to show the addition of a second I/O, DB
connector.
2.6 and 3.5
Corrected over all length dimension. It was 21.8" (554 mm), changed to 22.4" (570 mm).
3.17
Added HD4070 information to the DIP switch settings, table. This appeared in Revision 10.
3.18
Added old run rates (baud, data bits, stop bit, and parity). to serial protocol.
3.23
Correction. The notes reference on the right side of the table was changed from saying page 3-22 to
3-24.
Global
Changed
sensing
wires to
arc voltage
wires everywhere it appeared.
3g
Updated section to include the G3 series.
3i
Added the 260 and 400XD to the HPR setup section.
Added
section 3j
Added installation section for HySpeed HSD system.
6.4
Index No. 1 is now the entire assembly. The assemblies enclosure has been removed.
6.5
Added the drive nut, part number 127154. Added length (32.3125") to the description of the band
seal kit. Changed the quantity of the Rail and block bearing from 4 to 2.
6.7
Added items 3b (127155/proximity switch) and 3c (127156/collar).
6.8
Added 027665 (protective cover) and 2280557 (cable replacement kit).
6.9
Added the part numbers for the HPR400XD ohmic contact wires.
Section 7
Added wiring diagrams, 013369 (8 sheets).
Appendix A
Added older revision part numbers for the plasma interface assembly and the THC control module and
re-named the appendix to "parts list for older systems". It still includes the 1 rail lifter.
Added
Appendix B
Added pendant contrast adjustment procedure.