Power
Plasma
Supply
CNC
Interface
Signal Name
Color
End (1X6)
End
End
Function
Hold –
Black
5
Not
J4-6
(Optional)
Hold Ignition (I/O) signal used for preflow
Hold +
White
1
Connected
J4-5
during IHS. Also used by power unit to synchronize
Drain
Drain
10
operation of multiple torch installations. Output signal.
Plasma Start –
Black
9
Not
J4-4
Plasma Start signal maintained during plasma cut. If
Plasma Start +
Blue
15
Connected
J4-3
signal is lost, system must be restarted. Output signal.
Drain
Drain
14
Arc Transfer –
Black
32
Not
J3-2
Arc Transfer signal. Contact closes after arc transfer
Arc Tr
Red
37
Connected
J3-1
and pierce delay (set on power supply front panel).
Drain
Drain
26
Dry contact closure. Input signal.
Ramp Down Error
Black
28
28
Not
Ramp Down Error
Yellow
33
33
Connected
Drain
Drain
27
27
Not Used
Black
7
7
Not
These signals connect to the CNC. Refer to
Not Used
Brown
3
3
Connected
HT2000 LHF Instruction manual for signal information.
Drain
Drain
12
12
Not Used
Black
16
16
Not
Not Used
Green
17
17
Connected
Drain
Drain
18
18
HT2000LHF SETUP
3c-6
CommandTHC for X-Y Table
Instruction Manual
7
Figure 3c-3 HT2000LHF interface cable – part number and signal list
Part number
Description
Length
123329
HT2000LHF Power Supply Interface Cable
6 ft./1.8 m
Shaded area indicates plasma interface assembly connections.
Plasma interface assembly other J3 and J4 connection points:
• J3-5 (+) and J3-6 (–) – Alternate Nozzle Contact. An optically isolated signal that indicates nozzle is in ohmic contact with work.
Ohmic contact is represented by a logic 1.
• J3-7 through J3-12 – Reserved for future use.
• J3-13 and J3-14 – Protective earth ground.
• J4-1 (+) and J4-2 (–) – Available 24 VDC, 500 mA maximum
• J4-7 and J4-8 – Pierce Complete signal used by power supply to time transition from pierce gas flow to cut gas flow. User enters
this time delay into THC. Output signal.
• J4-9 through J4-14 – Reserved for future use.