MAX200 SETUP
CommandTHC for X-Y Table
Instruction Manual
3f-5
6
Figure 3f-2 MAX200 power supply interface cable connections
Pierce Complete-
Pierce C
Hold Ignition-
Hold I
Plasma Start
Plasma Start
24V -
24V +
8
7
6
5
4
3
2
1
J4
A
B
THC.78
B
4
3
2
1
J3
Pilot Arc-
Pilot Arc+
Transfer IN-
Transfer IN+
Plasma interface
assembly
Power supply
Red wire
Black wire
Black wire
White wire
Black wire
Green wire