SETUP
3-14
CommandTHC for X-Y Table
Instruction Manual
6
Machine interface cable
1. Cable-installed signal – See Figure 3-9.
The machine interface cable provides a signal to verify that the cable is installed properly. Continuity must be
provided through pins 3 and 22 so that the signal is not interrupted.
Install a jumper wire in the CNC to provide continuity between pins 3 and 22 when the machine interface cable is
installed to the CNC receptacle.
2. Emergency stop signal – See Figure 3-10.
The machine interface cable provides a signal for emergency stop. Continuity must be provided through pins 16 and
35 so that the signal is not interrupted.
Install a normally closed switch in the CNC to provide continuity between pins 16 and 35 when the machine
interface cable is installed to the CNC receptacle.
2
1
2
3
20
21
22
1
3
THC.86
Figure 3-9 CNC cable-installed signal
Machine interface cable
CNC receptacle
Jumper wire,
customer supplied
3
2
1
16
17
18
35
36
37
19
3
2
1
THC.85
Figure 3-10 CNC emergency stop signal
Machine interface cable
CNC receptacle
Stop switch,
customer supplied
3
2
1
CNC
CNC
To THC
control module