Chapter 7 Maintaining System
7-54
id
: Alarm ID, ranging 52–1572886.
II.
Setting by Alarm Level
Command line: (
no
)
alarm output alarmlevel
level
You may not concern about the alarms of lower level, and this
command can be used to set not output all the alarms of a certain
level.
level
: Alarm level. There are four levels: critical alarm, major
alarm, minor alarm and warning alarm. It is only necessary to input
the English word indicating the corresponding level directly.
III.
Setting by Alarm Type
Command: (
no
)
alarm output alarmtype
type_value
This command can enable the user to set alarm output by alarm
type.
type_value
: alarm type. There are five types: Communication
alarm, service_quality alarm, process_error alarm, equipment alarm
and environmental alarm. It is only necessary to input the English
word indicating the corresponding type directly.
IV.
Setting the Output of All Alarms
Command: (
no
)
alarm output all
After you have made a series of output settings, you may not
remember the output status. Therefore, the following command can
be used for setting the output flags for all alarms.