Chapter 7 Maintaining System
7-49
Item Description
startnum
The alarm number from which the display starts, the value range is
1–1000. In the Command Line Interface (CLI), you can start the
display from 1, or from a designated
startnum
.
number
Maximum number of alarm records after the
startnum
that can be
displayed in one time. It is an optional parameter, ranging 1–1000.
IV.
Querying by Alarm Type
show alarm record alarmtype
type_value
[
startnum number
]
You can use this command to query the alarms by alarm type.
The meanings of the parameters in the command are listed in
Table 7-13.
Table 7-13
Parameters of command
Item Description
type_value
Alarm type. There are five types: communication alarm,
service_quality alarm, process_error alarm, equipment alarm and
environmental alarm. It is only necessary to input the English word
indicating the corresponding type directly.
startnum
The alarm number from which the display starts, the value range is
1–1000. In the Command Line Interface (CLI), you can start the
display from 1, or from a designated
startnum
.
number
Maximum number of alarm records after the
startnum
that can be
displayed in one time. It is an optional parameter, ranging 1–1000.